Metered dose inhalers versus nebulizers for aerosol bronchodilator delivery for adult patients receiving mechanical ventilation in critical care units
- 6 June 2013
- journal article
- research article
- Published by Wiley in Cochrane Database of Systematic Reviews
- Vol. 2018 (12) , CD008863
- https://doi.org/10.1002/14651858.cd008863.pub2
Abstract
Nebulizers and metered dose inhalers (MDI) have both been adapted for delivering aerosol bronchodilation to mechanically ventilated patients, but there is incomplete knowledge as to the most effective method of delivery. To compare the effectiveness of nebulizers and MDIs for bronchodilator delivery in invasively ventilated, critically ill adults. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 5); Ovid MEDLINE (1950 to Week 19 2012); Ovid EMBASE (1980 to Week 19 2012); CINAHL via EBSCOhost (1982 to Week 19 2012) and reference lists of articles. We searched conference proceedings and reference lists of articles. We also contacted manufacturers and researchers in this field. There were no constraints based on language or publication status. Randomized controlled trials (RCTs), including randomized cross-over trials where the order of the intervention was randomized, comparing the nebulizer and MDI for aerosol bronchodilation in mechanically ventilated adult patients in critical care units. Two authors independently assessed trial quality and extracted data. We contacted study authors for additional information where required. We collected information about adverse effects from the trials. This review included three trials, two addressing the primary outcome measure of a reduction of airway resistance (measured as a reduction in interrupter and additional airway resistance) with a total of 28 patients (n =10, n =18) and two addressing adverse changes to haemodynamic observations with a total of 36 patients (n =18, n =18). Limitations in data availability and reporting in the included trials precluded meta-analysis and therefore the present review consisted of a descriptive analysis. Risk of bias in the included trials was judged as low or of unknown risk across the majority of items in the 'Risk of bias' tool.Cautious interpretation of the included study results suggests that nebulizers could be a more effective method of bronchodilator administration than MDI in terms of a change in resistance. No apparent changes to haemodynamic observations (measured as an increase in heart rate) were associated with either mode of delivery. Due to missing data issues, meta analyses were not possible. Additionally, small sample sizes and variability between the studies with regards to patient diagnoses, bronchodilator agent and administration technique mean that it would be speculative to infer definitive recommendations based on these results at this time. This is insufficient evidence to determine which is the most effective delivery system between nebuliser and MDI for aerosol bronchodilation in adult patients receiving mechanical ventilation. Existing randomized controlled trials, including randomized cross-over trials where the order of the intervention was randomized, comparing nebulizer and MDI for aerosol bronchodilation in mechanically ventilated adult patients do not provide sufficient evidence to support either delivery method at this time.Keywords
This publication has 35 references indexed in Scilit:
- A Comparison of Bronchodilator Therapy Delivered by Nebulization and Metered-Dose Inhaler in Mechanically Ventilated PatientsChest, 1999
- Inhaled Fenoterol–Ipratropium Bromide in Mechanically Ventilated Patients with Chronic Obstructive Pulmonary DiseaseAmerican Journal of Respiratory and Critical Care Medicine, 1999
- Bronchodilator response with use of OptiVent versus Aerosol Cloud Enhancer metered-dose inhaler spacers in patients receiving ventilatory assistance.Heart & Lung, 1998
- Efficiency of Bronchodilator Aerosol Delivery to the Lungs From the Metered Dose Inhaler in Mechanically Ventilated PatientsChest, 1994
- Metered-Dose Inhaler Versus Nebulized Albuterol in Mechanically Ventilated PatientsAmerican Review of Respiratory Disease, 1993
- Disposable Jet NebulizersChest, 1992
- Metered Dose Inhalers for Bronchodilator Delivery in Intubated, Mechanically Ventilated PatientsChest, 1991
- Pressurized Aerosol versus Jet Aerosol Delivery to Mechanically Ventilated Patients Comparison of Dose to the LungsAmerican Review of Respiratory Disease, 1990
- Bronchodilators in Patients with Chronic Obstructive Pulmonary Disease on Mechanical Ventilation: Utilization of Metered-dose InhalersAmerican Review of Respiratory Disease, 1990
- Bronchodilatation with a Metered-Dose Inhaler Plus an Extension, Using Tidal Breathing vs Jet NebulizationChest, 1987