An improved multiple internal standard normalisation for drift in LA-ICP-MS measurements
- 1 January 2002
- journal article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (11) , 1461-1470
- https://doi.org/10.1039/b207715a
Abstract
One of the primary factors limiting precision in LA-ICP-MS measurements is the instrument fluctuation. To overcome this limitation one usually employs a normalisation based on a single internal standard. This article reports a new approach for the normalisation of LA-ICP-MS measurements, based on multiple internal standards. The novelty of the approach is that it (i) takes into account the measurement uncertainties, (ii) generates uncertainty bounds on the normalized measurements and (iii) allows one to check and dismiss the mass dependency of the normalisation procedure. As a result, it is shown that the improvement in normalisation factor increases proportionally to the square root of the number of internal standards (e.g., the use of two internal standards leads to a decrease of the standard deviation by 30%, three to 42% and four up to 50% compared with the classical normalisation). This is illustrated on the NIST 610 standard with a 266 nm UV LA-ICP-MS. An extra advantage of the use of multiple internal standards is that it allows the detection of artifacts in the measurements (internal quality check).Keywords
This publication has 11 references indexed in Scilit:
- System IdentificationPublished by Wiley ,2001
- Recent trends and developments in laser ablation-ICP-mass spectrometryAnalytical and Bioanalytical Chemistry, 2000
- Automated in situ trace element analysis of silicate materials by laser ablation inductively coupled plasma mass spectrometryAnalytical and Bioanalytical Chemistry, 2000
- Application of a frequency quintupled Nd:YAG source (λ=213 nm) for laser ablation inductively coupled plasma mass spectrometric analysis of mineralsJournal of Analytical Atomic Spectrometry, 1998
- Dependence of detector dead time on analyte mass number in inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1998
- Order estimation for linear time-invariant systems using frequency domain identification methodsIEEE Transactions on Automatic Control, 1997
- Application of Laser Sampling Microprobe Inductively Coupled Plasma Mass Spectrometry to theIn Situ Trace Element Analysis of Selected Geological MaterialsJournal of Analytical Atomic Spectrometry, 1997
- An improved sine-wave fitting procedure for characterizing data acquisition channelsIEEE Transactions on Instrumentation and Measurement, 1996
- Sources of error in external calibration ICP-MS analysis of geological samples and an improved non-linear drift correction procedureSpectrochimica Acta Part B: Atomic Spectroscopy, 1993
- Solid sample introduction by laser ablation for inductively coupled plasma source mass spectrometryThe Analyst, 1985