Validity of dual X-ray absorptiometry scanning for determination of body composition in IDDM patients
- 1 January 1995
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 55 (8) , 691-699
- https://doi.org/10.3109/00365519509075399
Abstract
Data on body composition in patients with insulin-dependent diabetes mellitus (IDDM) are scarce. Dual X-ray absorptiometry (DXA) scanning has proved useful for this purpose in other groups of patients. We tested the validity of the DXA scanner for the determination of fat-free mass (FFM) and fat mass in IDDM patients and control subjects, as compared to other reference methods, i.e. total body potassium by 40K whole body counting (TBK), total body water by tritiated water (TBW), bioelectrical impedance analysis (BIA) and 24-h urinary creatinine excretion (Ucrea). A total of 13 healthy controls, 5 males and 8 females, aged 34.2 years +/- SD 10.4, and 11 IDDM patients, 5 males, 6 females, aged 28.1 years +/- 7.3, diabetes duration 4.2 +/- 2.9 (1.0-9.9), were examined. The patients had no long-term diabetic complications and they had normal ophthalmoscopy and urine albumin excretion. The agreement between FFM estimated by DXA and the other methods, expressed as mean difference +/- 2 SD was; for DXA vs. TBK, 0.09 +/- 6.26 and 0.50 +/- 5.26 kg for controls and IDDM patients respectively; DXA vs. TBW, -2.07 +/- 2.56 and -1.07 +/- 4.58 kg; DXA vs. Ucrea, -2.62 +/- 8.02 and 2.00 +/- 10.0 kg; DXA vs. BIA, -7.90 +/- 8.92 and -7.85 +/- 2.32 kg. The results obtained with BIA were significantly different from the other methods for both control subjects and IDDM patients. In conclusion, DXA scanning is a precise and valid method for estimation of fat-free mass in IDDM patients.Keywords
This publication has 15 references indexed in Scilit:
- Creatinine Height Index and Lean Body Mass in Adult Patients With Insulin‐Dependent Diabetes Mellitus Followed for 7 Years From OnsetJournal of Parenteral and Enteral Nutrition, 1994
- Accuracy of measurements of body composition by dual-energy x-ray absorptiometry in vivoThe American Journal of Clinical Nutrition, 1993
- Four-component model for the assessment of body composition in humans: comparison with alternative methods, and evaluation of the density and hydration of fat-free massClinical Science, 1992
- Total-body potassium in insulin-dependent diabetes mellitusClinical Science, 1990
- Urinary creatinine excretion and lean body massThe American Journal of Clinical Nutrition, 1976
- Studies on Whole-body Potassium in Non-ketoacidotic Diabetics Before and After TreatmentBMJ, 1974
- Exchangeable potassium in diabeticsMetabolism, 1966
- ISOTOPIC STUDIES OF POTASSIUM METABOLISM IN DIABETES 12Journal of Clinical Investigation, 1953
- STUDIES ON BODY COMPOSITIONJournal of Biological Chemistry, 1945
- ON THE COLORIMETRIC DETERMINATION OF CREATININE BY THE JAFFE REACTIONJournal of Biological Chemistry, 1945