Evaluation of a Time-Resolved Immunofluorometric Assay for Serum Thyroid Stimulating Hormone
- 1 November 1985
- journal article
- research article
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 22 (6) , 606-611
- https://doi.org/10.1177/000456328502200609
Abstract
The LKB ‘Delfia™’ immunofluorometric assay for serum TSH has been evaluated. The assay is simple and rapid to perform and is capable of processing in excess of 100 specimens within a working day. The sensitivity of the assay is 0·05 mU/L, with a working range extending beyond 324 mU/L. The change in signal at each point over the standard curve approaches 1000-fold, significantly greater than that of a typical immunoradiometric assay. Mean figures for intra-assay and inter-assay precision were 4·7% and 8·6% CV, respectively. Mean recovery of added TSH was 98·3%, and samples containing high levels of endogenous TSH diluted parallel to the standard curve. The method showed good correlation with an immunoradiometric assay for TSH. The reference ranges for clinically defined groups of subjects were euthyroid 0·47–3·84 mU/L ( n = 83); primary hypothyroidism 15 — >324 mU/L ( n = 28); thyrotoxicosis <0·05 mU/L ( n = 46). It is concluded that the ‘Delfia’ assay offers the clinical biochemistry laboratory an attractive and reliable alternative to a sensitive immunoradiometric assay for serum TSH.This publication has 11 references indexed in Scilit:
- A sensitive immunoradiometric assay for serum thyroid stimulating hormone: a replacement for the thyrotrophin releasing hormone test?BMJ, 1984
- FIRST-LINE TEST OF THYROID FUNCTIONThe Lancet, 1984
- Time-resolved fluoroimmunoassay of human pancreatic phospholipase A2.Clinical Chemistry, 1983
- Enhanced luminescence procedure for sensitive determination of peroxidase-labelled conjugates in immunoassayNature, 1983
- ULTRARAPID AND HIGHLY SENSITIVE TIME-RESOLVED FLUOROIMMUNOMETRIC ASSAY FOR CHORIONIC GONADOTROPINThe Lancet, 1983
- Time-resolved fluorometer for lanthanide chelates--a new generation of nonisotopic immunoassays.Clinical Chemistry, 1983
- Time-resolved fluoroimmunoassay of human choriogonadotropin.Clinical Chemistry, 1983
- Detection of hepatitis B surface antigen using time-resolved fluoroimmunoassayNature, 1983
- Time-resolved fluoroimmunoassay: a new test for rubella antibodiesJournal of Clinical Microbiology, 1982
- Fluoroimmunoassay: present status and key problems.Clinical Chemistry, 1979