Positron Emission Tomography Compared with Magnetic Resonance Imaging and Computed Tomography in Supratentorial Gliomas Using Multiple Stereotactic Biopsies as Reference
- 1 May 1989
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 30 (3) , 225-232
- https://doi.org/10.1177/028418518903000301
Abstract
Ten patients with findings at computed tomography (CT) suggesting intracranial supratentorial glioma were investigated to compare the diagnostic efficacy of this technique with that of positron emission tomography (PET) using11C-methionine and exminations with magnetic resonance (MR). The findings were related to histopathologic examination of serial stereotactic biopsies, which were guided by the appearance of the lesions on PET examination. To obtain corresponding slice orientation with the different examination techniques, an individually shaped helmet fixation was used. However, in 3 cases this fixation device could not be used for MR. Histopathologic diagnosis, obtained in all cases from multiple target stereotactic biopsies, included glioma in 9 patients and reactive gliosis in one case. A detailed comparison of the three imaging techniques and the findings at stereotactic biopsies was possible in 7 patients, while in 3 patients comparison with MR was less exact due to the patient's refusal to wear the helmet during this examination. MR was the most accurate method for outlining the total extent of a lesion, i.e. the tumor and the edema surrounding it. Four lesions had homogeneous signal characteristics and in 6 lesions two (or more) compartments could be distinguished with MR. In 5 cases the MR findings were in complete agreement with the histopathologic findings. However, a thorough correlation between signal characteristics and histology was not possible. Using PET the occurrence and the extent of tumor tissue was correctly predicted in 7 patients. The PET was normal in one case. Findings at CT were in agreement with the histopathologic diagnosis in 5 patients. MR was the most sensitive method for the detection of lesions. PET using methionine appeared to have a somewhat higher capacity to outline correctly the true extent of a tumor. The combination of CT and PET was superior to MR for determining the type and grade of the tumors.Keywords
This publication has 20 references indexed in Scilit:
- Die Aufnahme von Aminosäuren in Hirntumoren mit der Positronen-Emissionstomographie als Indikator für die Beurteilung von Stoffwechselaktivität und MalignitätRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1987
- 11C-Methionin-PET, IMP-SPECT, CT und MRI bei HirntumorenRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1985
- Positron Emission Tomography with ([11C]Methyl)-L-Methionine, [11C]D-Glucose, and [68Ga]EDTA in Supratentorial TumorsJournal of Computer Assisted Tomography, 1985
- Vergleichende MR- und CT-Untersuchungen bei ausgewählten neuroradiologischen FragestellungenRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1985
- The Use and Promise of Nuclear Magnetic Resonance Imaging in EpilepsyEpilepsia, 1984
- Discrepancies in Brain Tumor Extent as Shown by Computed Tomography and Positron Emission Tomography Using [68Ga]EDTA, [11C]Glucose, and [11C]MethionineJournal of Computer Assisted Tomography, 1983
- Design Characteristics of a Multiring Positron Camera System for Emission Tomography of the BrainPublished by Springer Nature ,1983
- Quantitation in Positron Emission Computed Tomography: 5. Physical–Anatomical EffectsJournal of Computer Assisted Tomography, 1981
- Head Fixation Device for Reproducible Position Alignment in Transmission CT and Positron Emission TomographyJournal of Computer Assisted Tomography, 1981
- Stereotaxic computerized tomography with a GE 8800 scannerJournal of Neurosurgery, 1980