Determination of MK‐0431 in human plasma using high turbulence liquid chromatography online extraction and tandem mass spectrometry
- 15 March 2006
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (8) , 1169-1175
- https://doi.org/10.1002/rcm.2426
Abstract
A robust and sensitive method using high turbulence liquid chromatography (HTLC) online extraction with tandem mass spectrometry (MS/MS) for the determination of MK‐0431 in human plasma was developed and validated to support the clinical studies. This HTLC online extraction method eliminated the time‐consuming offline sample extraction procedures and significantly increased productivity. A narrow bore large particle size reversed‐phase column (Cyclone, 50 × 1.0 mm, 60 µm) and a BDS Hypersil C18 column (30 × 2.1 mm, 3 µm) were used as extraction and analytical columns, respectively. The linear dynamic range of the calibration curve was 0.5 to 1000 ng/mL. Intraday validation was conducted using five calibration curves prepared in five lots of human control plasma, and the intraday precision (RSD%) was from 2.4 to 9.0% and the accuracy was from 98.0 to 103% of the nominal value. The intraday precision (RSD%, n = 5) for plasma quality control (QC) samples varied from 2.0 to 5.3% and accuracy from 103 to 105% of the nominal value. The interday precision (RSD%) for 100 sets of plasma QC samples in 29 analytical runs varied from 6.3 to 9.0% and the accuracy from 98.8 to 104% of the nominal value. No significant difference was observed between the interday and intraday precision and accuracy of the QC samples. Copyright © 2006 John Wiley & Sons, Ltd.Keywords
This publication has 19 references indexed in Scilit:
- (2R)-4-Oxo-4-[3-(Trifluoromethyl)-5,6-dihydro[1,2,4]triazolo[4,3-a]pyrazin- 7(8H)-yl]-1-(2,4,5-trifluorophenyl)butan-2-amine: A Potent, Orally Active Dipeptidyl Peptidase IV Inhibitor for the Treatment of Type 2 DiabetesJournal of Medicinal Chemistry, 2004
- A rapid and sensitive liquid chromatography/negative ion tandem mass spectrometry method for the determination of an indolocarbazole in human plasma using internal standard (IS) 96‐well diatomaceous earth plates for solid‐liquid extractionRapid Communications in Mass Spectrometry, 2002
- Determination of a β3-agonist in human plasma by LC/MS/MS with semi-automated 48-well diatomaceous earth plateJournal of Pharmaceutical and Biomedical Analysis, 2001
- High-throughput approaches to the quantitative analysis of ketoconazole, a potent inhibitor of cytochrome P450 3A4, in human plasmaRapid Communications in Mass Spectrometry, 2000
- Quantitative analysis of terbinafine (Lamisil ) in human and minipig plasma by liquid chromatography tandem mass spectrometryRapid Communications in Mass Spectrometry, 2000
- Comparison of turbulent-flow chromatography with automated solid-phase extraction in 96-well plates and liquid–liquid extraction used as plasma sample preparation techniques for liquid chromatography–tandem mass spectrometryJournal of Chromatography A, 1999
- A versatile system of high-flow high performance liquid chromatography with tandem mass spectrometry for rapid direct-injection analysis of plasma samples for quantitation of a β-lactam drug candidate and its open-ring biotransformation productRapid Communications in Mass Spectrometry, 1999
- The use of high-flow high performance liquid chromatography coupled with positive and negative ion electrospray tandem mass spectrometry for quantitative bioanalysis via direct injection of the plasma/serum samplesRapid Communications in Mass Spectrometry, 1998
- High-throughput solid-phase extraction for the determination of cimetidine in human plasmaJournal of Chromatography B: Biomedical Sciences and Applications, 1998
- The use of turbulent flow chromatography/mass spectrometry for the rapid, direct analysis of a novel pharmaceutical compound in plasmaRapid Communications in Mass Spectrometry, 1997