Biodegradable Polymers for Orthopedic Applications: Synthesis and Processability of Poly (l-Lactide) and Poly (Lactide-co-€-Caprolactone)
- 1 December 1993
- journal article
- research article
- Published by Taylor & Francis in Journal of Macromolecular Science, Part A
- Vol. 30 (12) , 933-947
- https://doi.org/10.1080/10601329308009437
Abstract
The synthesis of poly(l-lactide) (PLLA), poly(l-lactide-co-e-caprolactone), and poly(DL-lactide-co-e-caprolactone) by ring-opening bulk polymerization was investigated. Polymerization temperature had a significant effect on the PLLA molecular weight. At 184°C a polymer with a molecular weight of only 10 × 104 resulted. This was lower by a factor of 2 than that obtained at 103 and 145°C. The stannous octoate (SnOct) concentration, with a monomer/SnOct molar ratio in the range of 1,000 to 10,000, was not found to have a significant effect on the PLLA molecular weight. A heterogeneous structure in polymerized PLLA was observed. The intrinsic viscosity of poly(lactide-co-€-caprolactone), obtained at 130°C, monomer/SnOct molar ratio 5,000, and polymerization time of 30 hours, decreased with increasing €-caprolactone content within the first 9 wt% and then leveled off. Die-drawing of PLLA cylinders, for the purpose of increasing the polymer's mechanical strength, was unsuccessful due to the brittleness of the polymer. The drawability of poly(l-lactide), however, was greatly improved by copolymerization with €-caprolactone. With only 3 wt% of €-caprolactone, for example, the tensile strength of die-drawn poly(l-lactide-co-e-caprolactone) was increased by a factor of more than 3. Polymer processing temperature was also investigated. The requirement for low processing temperatures in melt manufacture of controlled release matrix devices containing thermal sensitive drugs was accomplished by three methods: through the use of low molecular weight poly(DL-lactide), adding (DL-lactic) acid oligomer to high molecular weight PDLLA, and copolymerizing DLLA with €-caprolactone. The glass transition temperatures of the modified high molecular weight PDLLA decreased significantly. Melt extrusion below 100°C could be performed.Keywords
This publication has 19 references indexed in Scilit:
- Biodegradable Polymers for Orthopedic ApplicationsJournal of Macromolecular Science, Part C: Polymer Reviews, 1993
- Biodegradable implants in orthopaedic surgery—A review on the state-of-the-artClinical Materials, 1992
- Preparation and characterization of biodegradable poly(l-lactic acid) gentamicin delivery systemsInternational Journal of Pharmaceutics, 1992
- Biodegradable controlled release tablets 1: Preparative variables affecting the properties of poly(lactide-co-glycolide) copolymers as matrix forming materialInternational Journal of Pharmaceutics, 1991
- The controlled parenteral delivery of polypeptides and proteinsInternational Journal of Pharmaceutics, 1990
- Synthesis and properties of biodegradable aliphatic polyestersBritish Polymer Journal, 1990
- Processing, structure and properties of oriented polymersMakromolekulare Chemie. Macromolecular Symposia, 1988
- Strength and strength retention vitro, of absorbable, self-reinforced polyglycolide (PGA) rods for fracture fixationBiomaterials, 1987
- Aliphatic polyesters. III. Molecular weight and molecular weight distribution in alcohol-initiated polymerizations of ε-caprolactoneJournal of Polymer Science: Polymer Chemistry Edition, 1982
- Polylactide. II. Viscosity–molecular weight relationships and unperturbed chain dimensionsJournal of Polymer Science: Polymer Chemistry Edition, 1979