Contact finite element stress analysis of the hip joint
- 1 January 1985
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 3 (4) , 435-446
- https://doi.org/10.1002/jor.1100030406
Abstract
Two-dimensional finite element analyses were conducted of the normal hip using contact elements at the joint surface. The models studied were constructed for a slice through the pubis, acetabulum, and ilium. In the analyses the proximal femur was pressed into the acetabulum and intraarticular pressures and principal stresses in the joint region were determined for different load magnitudes and directions and various boundary conditions. Three sets of boundary conditions were examined: (a) deformable pubic symphysis, (b) rigid pubic symphysis, and (c) simulations of experimental studies. In the deformable model the pubic symphysis was free to displace in the sagittal plane and rotate. In the rigid model the pubic symphysis was rigidly fixed. Superoposterior loading resulted in high-contact pressures at the acetabular dome for all sets of boundary conditions. For the deformable model subject to a more medially directed load the acetabulum closed in such a manner as to squeeze the head of the femur creating high-contact pressures superiorly and inferiorly. This resulted in significant compressive stresses in the superior dome cancellous bone and inferior cancellous bone. The cumulative effect of this squeezing action with normal biological remodeling may cause elongation of the femoral head resulting in asphericity and incongruity of the unloaded hip joint articular surfaces. Rigidly fixing the pubic symphysis stiffened the model and resulted in principal stress patterns that did not reflect trabecular density or orientations as well as those of the deformable pubic symphysis model. Finite element simulations of previous experimental studies modeled the close proximity of the fixation to the fixation to the excised acetablulum. These boundary conditions prevented the squeezing caused by pelvis deformations. The resulting contact areas, pressure distributions, and bone stresses were very different from those of more anatomic, deformable pubic symphysis model. These findings demonstrate the sensitivity of hip contact pressures and stresses to imposed boundary conditions and indicate that care should be taken to simulate anatomic conditions in experimental and theoretical studies.Keywords
This publication has 22 references indexed in Scilit:
- A contact-coupled finite element analysis of the natural adult hipJournal of Biomechanics, 1984
- Mechanical analysis of the human pelvis and its application to the artificial hip joint—By means of the three dimensional finite element methodJournal of Biomechanics, 1983
- In vitro contact stress distributions in the natural human hipJournal of Biomechanics, 1983
- Stress distributions in the acetabular region—I. Before and after total joint replacementJournal of Biomechanics, 1982
- An axisymmetric model of acetabular components in total hip arthroplastyJournal of Biomechanics, 1982
- Improved techniques for measuringin vitro the geometry and pressure distribution in the human acetabulum—II. Instrumented endoprosthesis measurement of articular surface pressure distributionJournal of Biomechanics, 1981
- Influence of Cartilage Geometry on the Pressure Distribution in the Human Hip JointScience, 1979
- Stresses in the normal pelvisComputers in Biology and Medicine, 1978
- The transmission of load through the human hip jointJournal of Biomechanics, 1971
- Incongruent Surfaces in the Human Hip JointNature, 1968