Improved method for detecting knee replacement infections based on extended combined99m Tc-white blood cell/bone imaging
- 1 October 2001
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 22 (10) , 1145-1150
- https://doi.org/10.1097/00006231-200110000-00015
Abstract
The purpose of this study was to evaluate whether an extension of the imaging time to 24 h post-injection improves the diagnostic accuracy of technetium-99m-hexamethylpropyleneamine oxime (99mTc-HMPAO) leucocyte imaging in detecting knee replacement infections. Thirty patients were studied, with infection confirmed in eight (27%) and excluded in 22 on the basis of clinical and microbiological findings. Leucocyte imaging was carried out at 2-4 h (routine images) and at 24 h (late images) post-injection. For comparison, bone imaging with technetium-99m-hydroxydiphosphonate (99mTc-HDP) was carried out at arterial, soft tissue and metabolic phases. Late leucocyte imaging was found to be more sensitive (100% vs. 87.5%) and more specific (82% vs. 77%) than routine leucocyte imaging in detecting infections. All the bone imaging methods showed a sensitivity of 100%, whereas the specificity varied from only 5% to 23%. All procedures had high negative predictive values (NPVs) (94 to 100%) for excluding infection. However, the positive predictive value (PPV) was only 28 to 32% for bone imaging and 58% for routine leucocyte imaging, whereas late leucocyte imaging showed a PPV of 67% and a diagnostic accuracy of 87%. The data indicate that late leucocyte imaging may be superior to routine leucocyte imaging for examining patients with symptomatic knee replacements.Keywords
This publication has 18 references indexed in Scilit:
- Imaging infection/inflammation in the new millenniumEuropean Journal of Nuclear Medicine and Molecular Imaging, 2001
- Complications of Total Hip Arthroplasty: MR Imaging—Initial ExperienceRadiology, 2000
- Infection After Total Knee Arthroplasty. A Retrospective Study of the Treatment of Eighty-One Infections*Journal of Bone and Joint Surgery, 1999
- Image technique optimization in MR imaging of a titanium alloy joint prosthesisJournal of Magnetic Resonance Imaging, 1996
- Evaluation of femoral prosthetic loosening using CT imaging.American Journal of Roentgenology, 1996
- Comparison of 99mTc Infecton imaging with radiolabelled white-cell imaging in the evaluation of bacterial infectionThe Lancet, 1996
- White cell scans and infected joint replacements. Failure to detect chronic infectionThe Journal of Bone and Joint Surgery. British volume, 1993
- Infected knee prosthesis: diagnosis with In-111 leukocyte, Tc-99m sulfur colloid, and Tc-99m MDP imaging.Radiology, 1991
- In-111-labeled leukocyte scintigraphy in suspected orthopedic prosthesis infection: comparison with other imaging modalities.Radiology, 1988
- Radiography, Radionuclide Imaging, and Arthrography in the Evaluation of Total Hip and Knee ReplacementRadiology, 1978