Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC technique
- 1 October 1998
- journal article
- Published by Wiley in Medical Physics
- Vol. 25 (10) , 1872-1879
- https://doi.org/10.1118/1.598376
Abstract
The use of intensity-modulated radiation fields in radiotherapy treatment has been shown to have the potential to deliver highly conformal dose distributions. One technique for delivering these intensity-modulated beams is a computerized dynamic multileaf collimator (MLC). A major current impediment to the development of dynamic MLC therapy is verification of these highly complex treatments. Electronic portal imaging is shown here to be a solution to this verification problem. Experimental results are presented showing that leaf penumbra measured with a portal imager can be used to accurately define the positions of moving leaves. The random error in these leaf positions is compared with mean leaf positions along each leaf bank and specified leaf positions at prescription control points to check mechanical performance. Individual leaves are also checked for systematic motion errors. All leaf positions are found to be well within the manufacturer's specifications at all times. Finally, integral intensity images are presented that can be related to the dose distribution delivered. Portal imaging is shown to have the potential to become a valuable tool for the verification of dynamic MLC irradiation.Keywords
This publication has 17 references indexed in Scilit:
- Testing of dynamic multileaf collimationMedical Physics, 1996
- Dosimetric verification of intensity‐modulated fieldsMedical Physics, 1996
- Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapyPhysics in Medicine & Biology, 1995
- Multifeaf collimation versus alloy blocks: Analysis of geometric accuracyInternational Journal of Radiation Oncology*Biology*Physics, 1995
- Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multileaf collimationsMedical Physics, 1994
- Dynamic X-ray compensation for conformal radiotherapy by means of multi-leaf collimationRadiotherapy and Oncology, 1994
- Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimatorsMedical Physics, 1994
- An analytical solution for the dynamic control of multileaf collimatorsPhysics in Medicine & Biology, 1994
- Measurement possibilities using an electronic portal imaging deviceRadiotherapy and Oncology, 1993
- The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimationPhysics in Medicine & Biology, 1992