Precision and Accuracy of a Procedure for Detecting Recent Human Immunodeficiency Virus Infections by Calculating the Antibody Avidity Index by an Automated Immunoassay-Based Method
Open Access
- 1 November 2002
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 40 (11) , 4015-4020
- https://doi.org/10.1128/jcm.40.11.4015-4020.2002
Abstract
We evaluated the precision and accuracy of a procedure for detecting recent human immunodeficiency virus (HIV) infections, specifically, the avidity index (AI) calculated using a method based on an automated AxSYM HIV 1/2gO assay (Abbott). To evaluate precision, we performed multiple replicates on eight HIV-positive serum samples. To evaluate the accuracy in identifying recent infections (i.e., within 6 months of seroconversion), we used 216 serum samples from 47 persons whose dates of seroconversion were known. To evaluate the sensitivity and specificity of the procedure for different AI cutoff values, we performed receiver operating characteristic (ROC) analysis. To determine the effects of antiretroviral treatment, advanced stage of the disease (i.e., low CD4-cell count), and low HIV viral load on the AI, we analyzed 15 serum samples from 15 persons whose dates of seroconversion were unknown. The precision study showed that the procedure was robust (i.e., the total variance of the AI was lower than 10%). Regarding accuracy, the mean AI was significantly lower for samples collected within 6 months of seroconversion, compared to those collected afterwards (0.68 ± 0.16 versus 0.99 ± 0.10; P < 0.0001), with no overlap of the 95% confidence intervals. The ROC analysis revealed that an AI lower than 0.6 had a sensitivity of 33.3% and a specificity of 98.4%, compared to 87.9 and 86.3%, respectively, for an AI lower than 0.9. Antiretroviral treatment, low CD4-cell count, and low viral load had no apparent effect on the AI. In conclusion, this procedure is reproducible and accurate in identifying recent infections; it is automated, inexpensive, and easy to perform, and it provides a quantitative result with different levels of sensitivity and specificity depending on the selected cutoff.Keywords
This publication has 21 references indexed in Scilit:
- Use of the sensitive/less-sensitive (detuned) EIA strategy for targeting genetic analysis of HIV-1 to recently infected blood donorsAIDS, 2002
- Evaluation of a Sensitive/Less-Sensitive Testing Algorithm Using the 3A11-LS Assay for Detecting Recent HIV Seroconversion among Individuals with HIV-1 Subtype B or E Infection in ThailandAIDS Research and Human Retroviruses, 2001
- Use of Immunoglobulin G Antibody Avidity for Differentiation of Primary Human Herpesvirus 6 and 7 InfectionsJournal of Clinical Microbiology, 2001
- Assessment of Antibody Assays for Identifying and Distinguishing Recent from Long-Term HIV Type 1 InfectionAIDS Research and Human Retroviruses, 2001
- Detection of Early HIV Infection and Estimation of Incidence Using a Sensitive/Less-Sensitive Enzyme Immunoassay Testing Strategy at Anonymous Counseling and Testing Sites in San FranciscoJAIDS Journal of Acquired Immune Deficiency Syndromes, 1999
- Differential maturation of avidity of IgG antibodies to gp41, p24 and p17 following infection with HIV-1Clinical and Experimental Immunology, 1996
- Measurement of antibody avidity for hepatitis C virus distinguishes primary antibody responses from passively acquired antibodyJournal of Medical Virology, 1994
- Antibody avidity following varicella-zoster virus infectionsJournal of Medical Virology, 1991
- Detection of IgM and IgA HIV antibodies after removal of IgG with recombinant protein GJournal of Immunological Methods, 1990
- Variations in Affinities of Antibodies during the Immune Response*Biochemistry, 1964