Performance of plate-based cytokine flow cytometry with automated data analysis
Open Access
- 1 January 2003
- journal article
- research article
- Published by Springer Nature in BMC Immunology
- Vol. 4 (1) , 9
- https://doi.org/10.1186/1471-2172-4-9
Abstract
Cytokine flow cytometry (CFC) provides a multiparameter alternative to ELISPOT assays for rapid quantitation of antigen-specific T cells. To increase the throughput of CFC assays, we have optimized methods for stimulating, staining, and acquiring whole blood or PBMC samples in 96-well or 24-well plates. We have developed a protocol for whole blood stimulation and processing in deep-well 24- or 96-well plates, and fresh or cryopreserved peripheral blood mononuclear cell (PBMC) stimulation and processing in conventional 96-well round-bottom plates. Samples from both HIV-1-seronegative and HIV-1-seropositive donors were tested. We show that the percent response, staining intensity, and cell recovery are comparable to stimulation and processing in tubes using traditional methods. We also show the equivalence of automated gating templates to manual gating for CFC data analysis. When combined with flow cytometry analysis using an automated plate loader and an automated analysis algorithm, these plate-based methods provide a higher throughput platform for CFC, as well as reducing operator-induced variability. These factors will be important for processing the numbers of samples required in large clinical trials, and for epitope mapping of patient responses.Keywords
This publication has 14 references indexed in Scilit:
- Cytokine flow cytometry: a multiparametric approach for assessing cellular immune responses to viral antigensClinical Immunology, 2004
- Cytokine Flow CytometryPublished by Springer Nature ,2003
- Comparison of the ELISPOT and cytokine flow cytometry assays for the enumeration of antigen-specific T cellsJournal of Immunological Methods, 2003
- Cytokine flow cytometry: multiparametric approach to immune function analysisCytotherapy, 2003
- Beyond 51Cr release: new methods for assessing HIV-1-specific CD8+ T cell responses in peripheral blood and mucosal tissuesClinical and Experimental Immunology, 2002
- Use of overlapping peptide mixtures as antigens for cytokine flow cytometryJournal of Immunological Methods, 2001
- Rapid quantification of SIV-specific CD8 T cell responses with recombinant vaccinia virus ELISPOT or cytokine flow cytometryAIDS, 2000
- Direct Visualization of Cytokine-Producing Recall Antigen-Specific CD4 Memory T Cells in Healthy Individuals and HIV PatientsThe Journal of Immunology, 2000
- Immunofluorescence Analysis of T-Cell Responses in Health and DiseaseJournal of Clinical Immunology, 2000
- Determination of antigen-specific memory/effector CD4+ T cell frequencies by flow cytometry: evidence for a novel, antigen-specific homeostatic mechanism in HIV-associated immunodeficiency.Journal of Clinical Investigation, 1997