Antibiotic‐Heparin Lock: In Vitro Antibiotic Stability Combined with Heparin in a Central Venous Catheter
- 1 April 2000
- journal article
- research article
- Published by Wiley in Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy
- Vol. 20 (4) , 394-399
- https://doi.org/10.1592/phco.20.5.394.35063
Abstract
Long‐term hemodialysis frequently requires vascular access through central venous catheters (CVCs). Infection related to these catheters is a significant complication. The use of an antibiotic‐heparin lock could decrease the risks associated with infected permanent catheters. As an initial step in developing an antibiotic‐heparin lock, we investigated the in vitro stability of antibiotic‐heparin combinations in CVCs. Initially, cefazolin, vancomycin, ceftazidime, ciprofloxacin 10 mg/ml each, and gentamicin 5 mg/ml were incubated separately in glass test tubes in the dark at 37°C for 72 hours. Samples were analyzed spectrophotometrically for stability at 24‐hour intervals. The procedure was repeated with the addition of heparin (final concentration 5000 U/ml in glass test tubes), and the combination was also examined in CVCs. High‐performance liquid chromatography analysis was conducted on the antibiotic‐heparin combinations at 72 hours to confirm the spectrophotometric results. Ciprofloxacin produced an immediate precipitate with the addition of heparin and was not analyzed further. Absorbance values decreased for all antibiotics, with the greatest decreases at 72 hours for cefazolin (27.4%), vancomycin (29.7%), ceftazidime (40.2%), and gentamicin (8%) when combined with heparin. These decreases were postulated to be secondary to adsorption of the antibiotics to the luminal surface of the catheters because submitting the catheters to ultrasound with 1% sodium bicarbonate and analyzing the resulting solution for absorbance revealed that some of the drug was recovered. Although free antibiotic in CVC solution was reduced, the concentration should be sufficient (approximately 5 mg/ml) to decrease the frequency of infections associated with CVCs. We conclude that the concentrations of vancomycin, ceftazidime, cefazolin, or gentamicin used in our study should be sufficient for an antibiotic‐heparin lock.Keywords
This publication has 27 references indexed in Scilit:
- Catheter-Related Bacteremia and Outcome of Attempted Catheter Salvage in Patients Undergoing HemodialysisAnnals of Internal Medicine, 1997
- Long-Term Survival of Vascular Accesses in a Large Chronic Hemodialysis PopulationNephron, 1995
- Central Venous Angioaccess for Hemodialysis and Its ComplicationsSeminars in Dialysis, 1992
- Prevention of hemodialysis subclavian vein catheter infections by topical povidone-iodineKidney International, 1991
- Post Catheterisation Vein Stenosis in Haemodialysis: Comparative Angiographic Study of 50 Subdavian and 50 Internal Jugular AccessesNephrology Dialysis Transplantation, 1991
- Use of a Silicone Dual-Lumen Catheter With a Dacron Cuff as a Long-Term Vascular Access for Hemodialysis PatientsAmerican Journal of Kidney Diseases, 1990
- Central Venous Access for Haemodialysis Using the Hickman CatheterNephrology Dialysis Transplantation, 1989
- Prospective Evaluation of a Dacron Cuffed Hemodialysis Catheter for Prolonged UseAmerican Journal of Kidney Diseases, 1988
- A Prospective Study of the Mechanisms of Infection Associated with Hemodialysis CathetersThe Journal of Infectious Diseases, 1986
- Infections Associated with Subclavian Dialysis Catheters: The Key Role of Nurse TrainingNephron, 1986