A method for bio-electrical impedance analysis based on a step-voltage response
- 1 August 2000
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 21 (3) , 395-408
- https://doi.org/10.1088/0967-3334/21/3/305
Abstract
Bioimpedance analysis (BIA) has been researched broadly, since it is simple, it presents good results and the analysers are portable, allowing it to be used in field studies. This paper presents a new technique of BIA based on a step-voltage current response and bipolar electrode array. A prototype of this new kind of analyser was developed and constructed to test the technique. Bench tests were performed to calibrate the prototype and the obtained results were comparable to those of commercial analysers. Body composition tests were conducted on 67 subjects of both sexes. Besides the bioimpedance analysis, anthropometric measures, consisting of weight, height, circumference and skinfold thickness, were also obtained from the subjects to allow an estimation of the body composition from anthropometric equations established in the literature. The results point to a good correlation (Pearson coefficient, r = 0.9645) between the anthropometric estimated fat-free mass (FFM) and its analogue estimated by the new bioimpedance technique.Keywords
This publication has 27 references indexed in Scilit:
- Bioelectrical Impedance and Body Composition: Present Status and Future DirectionsNutrition Reviews, 2009
- Phase angle spectrum analysis and body waterApplied Radiation and Isotopes, 1998
- Effect of temperature and sweating on bioimpedance measurementsApplied Radiation and Isotopes, 1998
- Sources of error in bioimpedance spectroscopyPhysiological Measurement, 1998
- Mechanical and physiologic modifiers and bioelectrical impedance spectrum determinants of body compositionThe American Journal of Clinical Nutrition, 1996
- Limitations of the bioelectrical impedance method for the assessment of body fat in severe obesityThe American Journal of Clinical Nutrition, 1996
- Alteration of the extracellular and total body water volumes measured by multiple frequency bioelectrical impedance analysis (MFBIA)Nutrition Research, 1994
- Between-laboratory comparison of densitometry and bio-electrical impedance measurementsBritish Journal of Nutrition, 1994
- Body fat assessed from total body density and its estimation from skinfold thickness: measurements on 481 men and women aged from 16 to 72 YearsBritish Journal of Nutrition, 1974
- THREE‐COMPONENT BODY COMPOSITION ANALYSIS BASED ON POTASSIUM AND WATER DETERMINATIONS*Annals of the New York Academy of Sciences, 1963