Abstract
Presents some values of electron density for normal human tissues. The work reported consists of in vitro Compton scatter density measurements on specimens of various human tissues, together with the calculation of ranges of electron density for these tissue types for comparison.Keywords
This publication has 10 references indexed in Scilit:
- Progress toward Quantitative Computed TomographyIEEE Transactions on Nuclear Science, 1980
- Compton-scatter tissue densitometry: calculation of single and multiple scatter photon fluencesPhysics in Medicine & Biology, 1978
- Measurement of effective atomic number and electron density using an EMI scannerNeuroradiology, 1976
- ATTENUATION OF MONOENERGETIC GAMMA RAYS IN TISSUESAmerican Journal of Roentgenology, 1975
- Human Tissues: Chemical Composition and Photon-Dosimetry Data. A CorrectionRadiation Research, 1974
- Human Tissues: Chemical Composition and Photon Dosimetry DataRadiation Research, 1974
- A new method for measurement of bone mineral content using both transmitted and scattered beams of gamma-raysPhysics in Medicine & Biology, 1973
- A Photon Scattering Technique for the Measurement of Absolute Bone Density in ManRadiology, 1973
- Effective Atomic Numbers of Heterogeneous MaterialsNature, 1965