0.04 µm Domain Expansion Readout for the Magnetic Amplifiying Magneto Optical System
- 1 February 2000
- journal article
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 39 (2S)
- https://doi.org/10.1143/jjap.39.725
Abstract
Read/write characteristics of the magnetic amplifying magneto optical system (MAMMOS) with alternative readout fields such as carrier to noise ratio (C/N), eye pattern, jitter and bit error rate (BER), are investigated with a 640 nm wavelength laser diode and 0.55 numerical aperture of the objective lens. The C/N value of 0.12 µm is 50 dB and is independent of the mark length. A very clear eye pattern was observed. The results show that the jitter value is less than 3% compared with the window width and it is only dependent on the switching speed of the readout field. The error rate is improved by using a thin recording layer of 50 nm in thickness. The minimum domain length which yields a BER of less than 1×10-4 is 0.045 µm (45 nm); the minimum space length is 0.10 µm (100 nm). These results are confirmed at a track pitch of about 0.40 µm. By using a digital versatile disk (DVD) pickup, the areal density can be estimated to be about 23 Gbit/in2 with the user data capacity of 30 GB/120 mmφ. By using a 400 nm blue laser diode, these values are estimated as 59 Gbit/in2 and 77 GB/120 mmφ.Keywords
This publication has 2 references indexed in Scilit:
- Evaluation of a 120 mm Sized Magneto optical Disk System of Over 6 GB CapacityJapanese Journal of Applied Physics, 1998
- Magnetic domain expansion readout for amplification of an ultra high density magneto-optical recording signalApplied Physics Letters, 1996