Assessment of Coronary Arteries with Total Study Time of Less than 30 Minutes by Using Whole-Heart Coronary MR Angiography
- 1 October 2005
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 237 (1) , 316-321
- https://doi.org/10.1148/radiol.2371040830
Abstract
This study had institutional review board approval, and all patients gave informed consent. The purpose of this study was to prospectively evaluate the use of whole-heart three-dimensional (3D) coronary magnetic resonance (MR) angiography in patients suspected of having coronary artery disease. Whole-heart coronary MR angiography was performed in 39 patients (30 men and nine women; mean age, 63.9 years +/- 15.6 [standard deviation]) by using a steady-state free precession sequence with free breathing. Twenty patients (16 men and four women; mean age, 64.9 years +/- 11.7) also underwent conventional coronary angiography. MR angiography was successfully completed in 34 of 39 patients (87%); the average imaging time was 13.8 minutes +/- 3.8. Sensitivity and specificity of MR angiography for detecting significant stenosis were 82% (14 of 17 arteries) and 91% (39 of 43 arteries), respectively. Whole-heart coronary MR angiography with a navigator-gated steady-state sequence can enable reliable 3D visualization of the coronary arteries in patients suspected of having coronary artery disease.Keywords
This publication has 19 references indexed in Scilit:
- Clinical utility of computed tomography and magnetic resonance techniques for noninvasive coronary angiographyJournal of the American College of Cardiology, 2003
- Coronary Artery Anomalies: Assessment with Free-breathing Three-dimensional Coronary MR AngiographyRadiology, 2003
- Coronary Magnetic Resonance Angiography: Technical Developments and Clinical ApplicationsJournal of Cardiovascular Magnetic Resonance, 2003
- Coronary Artery Imaging with Real-time Navigator Three-dimensional Turbo-Field-Echo MR Coronary Angiography: Initial ExperienceRadiology, 2003
- Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed TomographyCirculation, 2002
- High‐resolution selective three‐dimensional magnetic resonance coronary angiography with navigator‐echo technique: Segment‐by‐segment evaluation of coronary artery stenosisJournal of Magnetic Resonance Imaging, 2002
- Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiographyJournal of the American College of Cardiology, 1999
- Value of Electron-Beam Computed Tomography for the Noninvasive Detection of High-Grade Coronary-Artery Stenoses and OcclusionsNew England Journal of Medicine, 1998
- A Preliminary Report Comparing Magnetic Resonance Coronary Angiography with Conventional AngiographyNew England Journal of Medicine, 1993
- Coronary arteries: breath-hold MR angiography.Radiology, 1991