Reference dosimetry at the neutron capture therapy facility at Studsvik
- 16 June 2003
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 30 (7) , 1569-1579
- https://doi.org/10.1118/1.1580484
Abstract
The purpose of this publication was to present and evaluate the methods for reference dosimetry in the epithermal neutron beam at the neutron capture therapy facility at Studsvik. Measurements were performed in a PMMA phantom and in air using ionization chambers and activation probes in order to calibrate the epithermal neutron beam. Appropriate beam‐dependant calibration factors were determined using Monte Carlo methods for the detectors used in the present publication. Using the presented methodology, the photon, neutron and total absorbed dose to PMMA was determined with an estimated uncertainty of ±5.0%, ±25%, and ±5.5% (2 SD), respectively. The uncertainty of the determination of the photon absorbed dose was comparable to the case in conventional radiotherapy, while the uncertainty of the neutron absorbed dose is much higher using the present methods. The thermal neutron group fluence, i.e., the neutron fluence in the energy interval 0–0.414 eV, was determined with an estimated uncertainty of ±2.8% (2 SD), which is acceptable for dosimetry in epithermal neutron beams.Keywords
This publication has 14 references indexed in Scilit:
- IAEA/WHO TLD Postal Dose Audit Service and High Precision Measurements for Radiotherapy Level DosimetryRadiation Protection Dosimetry, 2002
- Photon quality correction factors for ionization chambers in an epithermal neutron beamPhysics in Medicine & Biology, 2002
- AAPM's TG‐51 protocol for clinical reference dosimetry of high‐energy photon and electron beamsMedical Physics, 1999
- Twin Ionisation Chambers for Dose Determiniations in Phantom in an Epithermal Neutron BeamRadiation Protection Dosimetry, 1999
- An improved neutron collimator for brain tumor irradiations in clinical boron neutron capture therapyMedical Physics, 1996
- The neutron sensitivity of dosimeters applied to boron neutron capture therapyMedical Physics, 1996
- Determination of dose components in phantoms irradiated with an epithermal neutron beam for boron neutron capture therapyMedical Physics, 1995
- Mixed field dosimetry of epithermal neutron beams for boron neutron capture therapy at the MITR‐II research reactorMedical Physics, 1994
- European protocol for neutron dosimetry for external beam therapyThe British Journal of Radiology, 1981
- Boron neutron capture therapy for the treatment of cerebral gliomas. I: Theoretical evaluation of the efficacy of various neutron beamsMedical Physics, 1975