Intrathoracic tumour motion estimation from CT imaging using the 3D optical flow method
- 20 August 2004
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 49 (17) , 4147-4161
- https://doi.org/10.1088/0031-9155/49/17/022
Abstract
The purpose of this work was to develop and validate an automated method for intrathoracic tumour motion estimation from breath-hold computed tomography (BH CT) imaging using the three-dimensional optical flow method (3D OFM). A modified 3D OFM algorithm provided 3D displacement vectors for each voxel which were used to map tumour voxels on expiration BH CT onto inspiration BH CT images. A thoracic phantom and simulated expiration/inspiration BH CT pairs were used for validation. The 3D OFM was applied to the measured inspiration and expiration BH CT images from one lung cancer and one oesophageal cancer patient. The resulting displacements were plotted in histogram format and analysed to provide insight regarding the tumour motion. The phantom tumour displacement was measured as 1.20 and 2.40 cm with full-width at tenth maximum (FWTM) for the distribution of displacement estimates of 0.008 and 0.006 cm, respectively. The maximum error of any single voxel's motion estimate was 1.1 mm along the z-dimension or approximately one-third of the z-dimension voxel size. The simulated BH CT pairs revealed an rms error of less than 0.25 mm. The displacement of the oesophageal tumours was nonuniform and up to 1.4 cm, this was a new finding. A lung tumour maximum displacement of 2.4 cm was found in the case evaluated. In conclusion, 3D OFM provided an accurate estimation of intrathoracic tumour motion, with estimated errors less than the voxel dimension in a simulated motion phantom study. Surprisingly, oesophageal tumour motion was large and nonuniform, with greatest motion occurring at the gastro-oesophageal junction.Keywords
This publication has 25 references indexed in Scilit:
- Intrafractional tumor motion: lung and liverSeminars in Radiation Oncology, 2004
- Introduction: intrafractional organ motion and its managementSeminars in Radiation Oncology, 2004
- Tracking moving organs in real timeSeminars in Radiation Oncology, 2004
- Multiple “slow” CT scans for incorporating lung tumor mobility in radiotheraphy planningInternational Journal of Radiation Oncology*Biology*Physics, 2001
- Dosimetric consequences of tumor mobility in radiotherapy of stage I non-small cell lung cancer – an analysis of data generated using ‘slow’ CT scansRadiotherapy and Oncology, 2001
- Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patientsMedical Physics, 2001
- Three-dimensional conformal radiation therapy may improve the therapeutic ratio of high dose radiation therapy for lung cancerInternational Journal of Radiation Oncology*Biology*Physics, 1993
- Computation of 3-D velocity fields from 3-D cine CT images of a human heartIEEE Transactions on Medical Imaging, 1991
- Principal warps: thin-plate splines and the decomposition of deformationsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1989
- Determining optical flowArtificial Intelligence, 1981