Preservation of platelet function on 2-methacryloyloxyethyl phosphorylcholine-graft polymer as compared to various water-soluble graft polymers
- 13 June 2001
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 57 (1) , 72-78
- https://doi.org/10.1002/1097-4636(200110)57:1<72::aid-jbm1143>3.0.co;2-g
Abstract
The chemical structures of water‐soluble polymers grafted onto PE surfaces affect platelet function when the platelets contact the polymer surfaces. To improve our understanding of this effect, this study sought to control the blood/materials interaction on the surfaces of polyethylene (PE) by grafting with various water‐soluble polymers. Such polymers as poly(2‐methacryloyloxyethyl phosphorylcholine) (PMPC), poly(acrylamide) (PAAm), poly(N‐vinylpyrrolidone) (PVPy), and poly[monomethacryloyl poly(ethylene glycol)] (PMPEG) were grafted on low‐density PE sheets by photoinduced graft polymerization. Both the PE bags modified with water‐soluble polymers and those nonmodified were prepared by heat processing. Activation of platelets after storage in the PE bags was evaluated by measuring the cytoplasmic free calcium ion concentration ([Ca2+]i). The concentration of [Ca2+]i of platelets in contact with the PE surface grafted with PMPC was the same as that of native platelets and significantly less than that in contact with other PE surfaces grafted with water‐soluble polymers. The number of adherent platelets was effectively decreased on PE surfaces grafted with PMPC and PMPEG, as compared with nontreated PE. The aggregation ability of platelets was also measured after storage of platelet‐rich plasma in the PE bags. The PE surface grafted with PMPC effectively maintained aggregation ability as compared with both the nontreated PE and with PE grafted with PAAm, PVPy, and PMPEG. It was concluded that for preserving platelet function, PMPC was the most effective of these water‐soluble polymers used for surface modification. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res 57: 72–78, 2001Keywords
This publication has 25 references indexed in Scilit:
- Why do phospholipid polymers reduce protein adsorption?Journal of Biomedical Materials Research, 1998
- Mechanism of cytoplasmic calcium changes in platelets in contact with polystyrene and poly(acrylamide-co-methacrylic acid) surfacesJournal of Biomaterials Science, Polymer Edition, 1993
- Review Does polyethylene oxide possess a low thrombogenicity?Journal of Biomaterials Science, Polymer Edition, 1993
- Calculation of solvation interaction energies for protein adsorption on polymer surfacesJournal of Biomaterials Science, Polymer Edition, 1992
- Interaction between phospholipids and biocompatible polymers containing a phosphorylcholine moietyBiomaterials, 1991
- Solution technique to incorporate polyethylene oxide and other water-soluble polymers into surfaces of polymeric biomaterialsBiomaterials, 1991
- Platelet Adhesion on Polymers Having Phospholipid Polar Group.KOBUNSHI RONBUNSHU, 1991
- The cytoplasmic concentration of free calcium in platelets is controlled by stimulators of cyclic AMP production (PGD2, PGE1, forskolin)Biochemical and Biophysical Research Communications, 1983
- Photo-induced change in wettability and binding ability of azoaromatic polymersJournal of Applied Polymer Science, 1982
- Photosensitized grafting on polyolefin films in vapor and liquid phasesJournal of Polymer Science Part C: Polymer Letters, 1981