Detection of plasmapheresis‐induced platelet activation using monoclonal antibodies
- 8 July 1992
- journal article
- Published by Wiley in Transfusion
- Vol. 32 (6) , 534-540
- https://doi.org/10.1046/j.1537-2995.1992.32692367197.x
Abstract
Twelve volunteer plasma donors were studied so as to determine the extent and duration of in vivo platelet activation caused by automated plasmapheresis. Samples obtained immediately before and after donation were mixed with murine monoclonal antibodies PAC-1 and S12, which bind specifically to activated platelets. Antibody binding on platelets was quantitated by flow cytometry. The change in the mean fluorescence intensity (MFI) (MFI after donation minus MFI before donation) was 61 +/- 23 (confidence interval [CI], 48-75) for PAC-1 and 56 +/- 64 (CI, 19-92) for S12 in plasmapheresis donors, as compared to 0.3 +/- 0.8 (PAC-1; CI, -0.2-0.8) and 0.3 +/- 0.9 (S12: CI, -0.3-0.9) in whole blood donors (p less than 0.05). Additional studies showed circulating activated platelets up to 48 hours after plasmapheresis. In contrast to other data, significant platelet activation was demonstrated following plasmapheresis on an automated machine. None of the donors had clinical complications. Nevertheless, it may be appropriate to delay subsequent plasmapheresis and platelet procurement from such donors until evidence of platelet activation has disappeared.Keywords
This publication has 23 references indexed in Scilit:
- Progressive platelet activation with storage: evidence for shortened survival of activated platelets after transfusionTransfusion, 1991
- The Canadian Red Cross Plasmapheresis Donor Safety Program: Changes in Plasma Proteins after Long‐Term PlasmapheresisVox Sanguinis, 1991
- Novel Markers for the Detection of Platelet ActivationTransfusion Medicine Reviews, 1990
- Side Effects of HemapheresisTransfusion Medicine Reviews, 1987
- Platelet Activation in Unstable Coronary DiseaseNew England Journal of Medicine, 1986
- Platelet surface glycoproteins. Studies on resting and activated platelets and platelet membrane microparticles in normal subjects, and observations in patients during adult respiratory distress syndrome and cardiac surgery.Journal of Clinical Investigation, 1986
- Plasma collection using an automated membrane deviceTransfusion, 1986
- The release of β‐ thromboglobulin and platelet factor 4 during extracorporeal circulation for open heart surgeryEuropean Journal of Clinical Investigation, 1981
- Elevated plasma fibrinopeptide A and thromboxane B2 levels during cardiopulmonary bypass.Circulation, 1980
- "EXHAUSTED" PLATELETS CONTINUE TO CIRCULATEThe Lancet, 1978