A unit for source and protective isolation in a general hospital.
- 25 August 1979
- Vol. 2 (6188) , 461-465
- https://doi.org/10.1136/bmj.2.6188.461
Abstract
An isolation unit consisting of 12 ventilated cubicles was investigated over 18 months. Out of 462 patients admitted, 262 (57%) required source and 200 (43%) protective isolation. Admissions of patients with staphylococcal sepsis fell from 16 in the first three months to six in the last three months. Staphylococcus aureus was recovered from 12% of nurses' fingers and often in small numbers from protective clothing and uniforms, but only two patients acquired a strain from a nurse or another patient. Gram-negative bacilli were rarely recovered from hands or protective clothing of nurses, and there was no evidence of spread of infectious diseases. This inexpensive unit, with simple but efficient isolation-nursing techniques, successfully prevented the spread of infection.Keywords
This publication has 12 references indexed in Scilit:
- DECLINE OF THE HOSPITAL STAPHYLOCOCCUS?The Lancet, 1979
- A test for 'hygienic' hand disinfection.Journal of Clinical Pathology, 1978
- Isolating patients in hospital to control infection part II--Who should be isolated, and where?BMJ, 1978
- An evaluation of handwashing techniques-2.1978
- Hands as route of transmission for Klebsiella species.BMJ, 1977
- An isolation unit in a district general hospital.BMJ, 1977
- Surveys of hospital infection in the Birmingham region: I. Effect of age, sex, length of stay and antibiotic use on nasal carriage of tetracycline-resistant Staphyloccus aureus and on post-operative wound infectionEpidemiology and Infection, 1977
- Transfer of Staphylococcus aureus via nurses' uniformsEpidemiology and Infection, 1973
- VARIETIES OF ASEPTIC PRACTICE IN HOSPITAL WARDSThe Lancet, 1969
- CONTAMINATION OF NURSES' UNIFORMS WITH STAPHYLOCOCCUS AUREUSThe Lancet, 1969