Improved Visualization of Coronary Arteries Using a New Three-Dimensional Submillimeter MR Coronary Angiography Sequence with Balanced Gradients
- 1 October 2002
- journal article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 179 (4) , 901-910
- https://doi.org/10.2214/ajr.179.4.1790901
Abstract
OBJECTIVE. The goal of our study was to evaluate a new three-dimensional real-time navigator MR coronary angiography sequence to noninvasively visualize the coronary arteries. SUBJECTS AND METHODS. Fifteen healthy volunteers underwent MR coronary angiography with a new balanced turbo field-echo sequence in comparison with the standard turbo field-echo sequence. Signal-to-noise, blood-to-myocardium, blood-to-fat, and blood-to-pericardial fluid contrast ratios of the left and right coronary artery systems were measured. Image quality was graded, the length and diameter of the coronary arteries were measured, and the number of visible side branches was assessed. RESULTS. The balanced turbo field-echo images yielded a higher blood-to-myocardium and blood-to-pericardial fluid contrast ratio, a similar blood-to-fat contrast ratio, and a lower signal-to-noise ratio than the turbo field-echo images. On a 5-point grading scale (1, nondiagnostic or unreadable; 2, poor; 3, moderate; 4, good; 5, excellent), image quality was rated significantly better for the balanced turbo field-echo sequence than for the turbo field-echo sequence (left coronary artery, 4.0 ± 0.6 vs 3.6 ± 0.5 [p = 0.015]; right coronary artery, 4.4 ± 0.4 vs 3.6 ± 0.4 [p < 0.0001], respectively), resulting in a significantly longer segment of the three major coronary arteries visualized (left anterior descending coronary artery, 92 ± 21 mm vs 79 ± 24 mm; left circumflex coronary artery, 70 ± 7 mm vs 60 ± 18 mm; right coronary artery, 112 ± 28 mm vs 95 ± 27 mm) and a significantly higher number of side branches visualized (left anterior descending coronary artery, 2.9 ± 1.3 vs 1.5 ± 1.3; left circumflex coronary artery, 2.1 ± 1.7 vs 1.0 ± 1.2; right coronary artery, 3.7 ± 1.7 vs 2.6 ± 1.5). Mean imaging time per coronary artery was significantly shorter for the balanced turbo field-echo sequence (5.7 ± 1.0 min) than for the turbo field-echo sequence (8.4 ± 1.4 min) (p < 0.0001). CONCLUSION. Compared with standard turbo field-echo MR coronary angiography, optimized balanced turbo field-echo MR coronary angiography improves the visualization of the coronary arteries and their side branches within a significantly shorter imaging time.Keywords
This publication has 32 references indexed in Scilit:
- Coronary Magnetic Resonance Angiography for the Detection of Coronary StenosesNew England Journal of Medicine, 2001
- Functional cardiac MR imaging with steady‐state free precession (SSFP) significantly improves endocardial border delineation without contrast agentsJournal of Magnetic Resonance Imaging, 2001
- Detection of Coronary Artery Stenoses by Contrast-Enhanced, Retrospectively Electrocardiographically-Gated, Multislice Spiral Computed TomographyCirculation, 2001
- MR Evaluation of Ventricular Function: True Fast Imaging with Steady-State Precession versus Fast Low-Angle Shot Cine MR Imaging: Feasibility StudyRadiology, 2001
- MR Coronary Angiography with Breath-hold Targeted Volumes: Preliminary Clinical ResultsRadiology, 2000
- Coronary arteriesEuropean Radiology, 2000
- Value of navigator echo magnetic resonance angiography in detecting occlusion/patency of arterial and venous, single and sequential coronary bypass graftsThe International Journal of Cardiovascular Imaging, 2000
- Submillimeter Three-dimensional Coronary MR Angiography with Real-time Navigator Correction: Comparison of Navigator LocationsRadiology, 1999
- Breath-hold coronary MR angiography with volume-targeted imaging.Radiology, 1998
- Single breath-hold volumetric imaging of the heart using magnetization-prepared 3-dimensional segmented echo planar imagingJournal of Magnetic Resonance Imaging, 1995