Development of a New Approach to Vascular Access
- 1 January 1999
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 23 (1) , 10-14
- https://doi.org/10.1046/j.1525-1594.1999.06286.x
Abstract
Three modes of access for hemodialysis (HD) have been available for over 20 years, the native arterial to venous (A‐V) fistula, the polytetrafluorethylene (PTFE) graft fistula, and the central venous catheter. Overall, vascular access remains the single most costly source of morbidity and hospitalization in HD patients, indicating a severe need for improvement in this area. A significant contributor to access morbidity is the HD catheter, which protrudes through the skin and is subject to frequent infection. Subcutaneous ports have been developed to overcome this problem with catheters, but their application to HD has been elusive for 2 reasons, the use of a degradable septum that becomes vulnerable to infection with the use of large bore needles and the presence of a nonlinear flow path which produces damage to blood cells and stimulates thrombus formation at the required high flow rates. A new device, the Dialock, overcomes these objections by its use of a mechanical valve that maintains a linear flow path without directly contacting the blood. Results of a pilot study with 23 patients demonstrated a 78% cumulative survival rate after 1 year with a reduced rate of infection compared to catheters and sustained blood flow of 330 ml/min. The device represents a most promising advance in vascular access.Keywords
This publication has 12 references indexed in Scilit:
- Initial results of a new access device for hemodialysis: Technical NoteKidney International, 1998
- New Access Device for HemodialysisAsaio Journal, 1998
- Longitudinal comparison of dialysis access methods: Risk factors for failureJournal of Vascular Surgery, 1997
- Catheter-Related Bacteremia and Outcome of Attempted Catheter Salvage in Patients Undergoing HemodialysisAnnals of Internal Medicine, 1997
- Double Catheterization of the Internal Jugular Vein for Hemodialysis: Indications, Techniques, and Clinical ResultsArtificial Organs, 1994
- Permanent Vascular Access: A Nephrologist's ViewAmerican Journal of Kidney Diseases, 1993
- Vancomycin Stability in Heparin and Total Parenteral Nutrition Solutions: Novel Approach to Therapy of Central Venous Catheter‐Related InfectionsJournal of Parenteral and Enteral Nutrition, 1992
- Experience with the Hemasite Device in Haemodialysis and Haemofiltration Patients with Vascular Access ProblemsNephrology Dialysis Transplantation, 1990
- Internal Jugular Vein Cannulation with Two Silicone Rubber Catheters: A New and Safe Temporary Vascular Access for Hemodialysis. Thirty Months' ExperienceArtificial Organs, 1986
- The Outcome and Complications of the DiaTAP bioCarbon® Button-Graft Vascular Access Device in Haemodialysis Patients: A Two-Year ExperienceNephron, 1986