Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities. I. Basic principles
- 1 July 1992
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 39 (4) , 489-495
- https://doi.org/10.1109/58.148539
Abstract
The use of a synthetic receive aperture (SRA) system to increase the resolution, of a phased-array imaging system severalfold, by utilizing the available number of parallel receiver channels to address a larger number of transducer elements through a multiplexer system, is considered. Recent studies indicate that transducers with a very large number of elements will improve the detectability of small or low contrast targets when adaptive focusing is used to compensate for the effects of acoustic velocity inhomogeneities in tissue. With the effectively increased transducer element count afforded by an SRA system, a 1-by-N phased array could be split into an M-by-N array in order to improve resolution in the elevation dimension. Simulation results illustrate the lateral resolution achievable with several types of imaging systems: SRA, synthetic focus, and conventional phased array. Simulated images demonstrate the improvement in contrast resolution achievable using SRA. Experimental results show the improvement in beam width achieved by an experimental SRA system.<>Keywords
This publication has 14 references indexed in Scilit:
- Preliminary study of a correlation based phase-aberration correction algorithm for correcting a single-source image through a refractive medium: The female breastPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- In Vivo Measurements of Ultrasonic Beam Distortion in the BreastUltrasonic Imaging, 1991
- A concave annular array design, based on phasor summation—Part I: Design methodologyUltrasonic Imaging, 1988
- Phase aberration measurements in medical ultrasound: Human studiesUltrasonic Imaging, 1988
- In vivo and in vitro ultrasound beam distortion measurements of a large aperture and a conventional aperture focussed transducerUltrasound in Medicine & Biology, 1987
- Accurate Reconstruction of Flaws in Materials Using a Synthetic Aperture Ultrasonic Imaging SystemPublished by Springer Nature ,1987
- A New Synthetic-Aperture Focusing Method for Ultrasonic B-Scan Imaging by the Fourier TransformIEEE Transactions on Sonics and Ultrasonics, 1985
- A Real-Time Synthetic Aperture Digital Acoustic Imaging SystemPublished by Springer Nature ,1982
- Nde Imaging with Multielement ArraysPublished by Springer Nature ,1982
- A 50 MHz Synthetic Focus SystemPublished by Springer Nature ,1982