Use of Foley Catheter for Removal of Esophageal Foreign Bodies a Survey
- 1 November 1982
- journal article
- research article
- Published by SAGE Publications in Annals of Otology, Rhinology & Laryngology
- Vol. 91 (6) , 599-601
- https://doi.org/10.1177/000348948209100614
Abstract
A survey was conducted among otolaryngologists, thoracic surgeons, pediatric surgeons and pediatric radiologists to determine the frequency of removal of esophageal foreign bodies with a Foley catheter. The 245 physicians responding reported 1,512 cases, 96% of which were treated with this technique by radiologists and pediatric surgeons. Although no deaths or serious complications were reported, the author warns that increasing use of this procedure by nonendoscopists carries the risk of serious complications unless certain safeguards are taken. These include trained personnel, use of fluoroscopy, a cooperative patient with a single, smooth, radiopaque foreign body lodged in the esophagus and a barium esophagogram with negative results for total obstruction and underlying esophageal disease.Keywords
This publication has 4 references indexed in Scilit:
- Questionable Methods of Foreign Body TreatmentAnnals of Otology, Rhinology & Laryngology, 1974
- Removal of Coins From the Esophagus: Nothing New Under the SunPediatrics, 1973
- Blind Esophageal Coin Removal Using a Foley CatheterArchives of Surgery, 1968
- The use of a Foley catheter for removal of blunt foreign bodies from the esophagusThe Journal of Thoracic and Cardiovascular Surgery, 1966