Optimal Interval for Triple-lumen Catheter Changes
- 1 June 1995
- journal article
- review article
- Published by SAGE Publications in Medical Decision Making
- Vol. 15 (2) , 138-142
- https://doi.org/10.1177/0272989x9501500206
Abstract
A survey of 53 university and community hospitals revealed that 73% of the institutions had no standard policy for the replacement of triple-lumen catheters (TLCs). Since the mainte nance of a TLC in place for a prolonged period may lead to infectious complications, it appeared warranted that standards of management be developed. A decision-tree model was constructed for evaluating the optimal time for changing a TLC that would minimize infection. Cost estimates and health effects at three-, five-, and ten-day change intervals were considered for catheter insertion and complications resulting from such insertion. The results suggested that prophylactic catheter changes should occur no later than every five days, provided that there are no signs of infection. However, sensitivity analysis of several variables suggested that individual institutions should establish policy timing changes based upon careful interpretation of their own data. A model was developed to assist in determining the optimal time to change a TLC based upon such data. Key words: triple-lumen catheter; catheter-related infection; sepsis; decision analysis. (Med Decis Making 1995;15:138-142)Keywords
This publication has 27 references indexed in Scilit:
- Infectious Complications of Indwelling Vascular CathetersClinical Infectious Diseases, 1992
- Central Catheter‐Related Infections: Comparison of Pulmonary Artery Catheters and Triple Lumen Catheters for the Delivery of Hyperalimentation in a Critical Care SettingJournal of Parenteral and Enteral Nutrition, 1990
- Catheter-related sepsisCritical Care Medicine, 1990
- Percutaneous central venous catheterization in a pediatric intensive care unitCritical Care Medicine, 1989
- Catheter InfectionAnnals of Surgery, 1988
- Central catheter infections: Single- versus triple-lumen catheters: Influence of guide wires on infection rates when used for replacement of cathetersThe American Journal of Medicine, 1988
- Septic and Technical Complications of Central Venous CatheterizationAnnals of Surgery, 1985
- Polymicrobial bloodstream infections related to prolonged vascular catheterizationCritical Care Medicine, 1984
- The Clinical Significance of Positive Blood Cultures: A Comprehensive Analysis of 500 Episodes of Bacteremia and Fungemia in Adults. I. Laboratory and Epidemiologic ObservationsClinical Infectious Diseases, 1983
- A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related InfectionNew England Journal of Medicine, 1977