25-gauge, sutureless vitrectomy and standard 20-gauge pars plana vitrectomy in idiopathic epiretinal membrane surgery: a comparative pilot study
- 19 January 2006
- journal article
- research article
- Published by Springer Nature in Albrecht von Graefes Archiv für Ophthalmologie
- Vol. 244 (4) , 472-479
- https://doi.org/10.1007/s00417-005-0173-6
Abstract
The aim of the study was to evaluate the safety and functional outcome of a small incision, sutureless vitrectomy in the treatment of idiopathic epiretinal membranes (ERM) compared with a standard 20-gauge vitrectomy system. Forty-six consecutive patients with idiopathic ERM were recruited for this study and prospectively evaluated. In group 1 (n=26) we used a transconjunctival sutureless 25-gauge vitrectomy system (TSV), patients in group 2 (n=20) were operated on using a standard 20-gauge vitrectomy system. The ERM was removed and the internal limiting membrane (ILM) was peeled in all eyes. Surgery-related complications, operating time, intraoperative balanced salt solution (BSS) consumption, postoperative discomfort, postoperative intraocular inflammation, lens opacification, and long-term visual outcome are reported and compared. No surgery-related complications were observed in either group. Operating time was shorter in group 1 compared with group 2 (mean 15.6 and 29.6 min respectively). Intraoperative amount of BSS consumption was less in group 1 (mean 28 ml in group 1 and 42 ml in group 2). Postoperative discomfort and intraocular inflammation were significantly reduced in the 25-gauge group. In the 20-gauge group cataract formation requiring surgery was observed in two eyes. Visual acuity improved significantly in both groups. The 25-gauge group improved on average by more lines of vision and the improvement in vision was more rapid. The TSV system is a safe and efficient surgical technique for ERM surgery. Operating time is significantly reduced, minimizing surgery-induced trauma, and reducing postoperative intraocular inflammation and the patients’ discomfort. The incidence of cataract formation may be less using TSV. Postoperative recovery is accelerated.Keywords
This publication has 23 references indexed in Scilit:
- A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch and Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch & Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Nonvitrectomizing vitreous surgery: A strategy to prevent postoperative nuclear sclerosisOphthalmology, 1999
- Sutureless Pars Plana Vitrectomy Through Self-sealing SclerotomiesArchives of Ophthalmology (1950), 1996
- The Lens Opacities Classification System IIIArchives of Ophthalmology (1950), 1993
- Vitrectomy for idiopathic epiretinal membranes causing macular pucker.British Journal of Ophthalmology, 1988
- Nuclear Sclerosis After Vitrectomy for Idiopathic Epiretinal MembranesAmerican Journal of Ophthalmology, 1988
- Surgical Management of Idiopathic Epiretinal MembranesOphthalmology, 1986
- Removal of Epimacular MembranesOphthalmology, 1985
- Vitroctomy for Macular PuckerOphthalmology, 1984