Determination of pesticides in aqueous samples by solid-phase microextraction in-line coupled to gas chromatography—mass spectrometry
- 1 November 1995
- journal article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 6 (11) , 1119-1130
- https://doi.org/10.1016/1044-0305(95)00527-7
Abstract
A multiresidue method was developed for the determination of nitrogen- and phosphorous-containing pesticides (amines, anilides, phosphorothioates, and triazines) by solid-phase microextraction (SPME) in-line coupled to gas chromatography—mass spectrometry (GC/MS). The 85-µm polyacrylate fiber was first dipped into the aqueous sample for a given time and then directly introduced into the heated injector of the gas chromatography—mass spectrometer, where the analytes are thermally desorbed. The method was evaluated with respect to the limit of detection, linearity, and precision. The limit of detection [selected ion monitoring (SIM) mode] depends on the compound and varies from 5 to 90 ng/L. The method is linear over at least 3 orders of magnitude with coefficients of correlation usually ≥0.996. In general, the coefficient of variation (precision) is P ow. The addition of sodium chloride has a strong effect on the extraction efficiency. This effect increases with decreasing hydrophobicity (increasing polarity) of the compound. The triazines atrazine, simazine, and terbuthylazine were first identified and quantified in water samples from the effluent of sewage plants by SPME-gas chromatography—nitrogen—phosphorus detection (GC/NPD). For such a complex matrix GC/NPD is not sufficiently selective for an unambiguous identification at low levels (<1 ppb) of pesticides. Selectivity may be enhanced by using SMPE-GC/MS in the SIM mode with three characteristic ions for each pesticide. This method allows an unequivocal identification and quantification at low levels of pesticides in environmental samples. At a target limit of detection below 100 ng/L, SPME-GC/MS represents a very simple, fast, selective, and solvent-free multimethod for the extraction and determination of these nitrogen- and phosphorous-containing pesticides from aqueous samples.Keywords
This publication has 31 references indexed in Scilit:
- Liquid-Solid Extraction and Fast Atom Bombardment High-Resolution Mass Spectrometry for the Determination of Hydroxyatrazine in Water at Low-ppt LevelsAnalytical Chemistry, 1994
- Solid-Phase Microextraction. A Solvent-Free Alternative for Sample PreparationAnalytical Chemistry, 1994
- Rapid determination of polyaromatic hydrocarbons and polychlorinated biphenyls in water using solid-phase microextraction and GC/MSEnvironmental Science & Technology, 1994
- Analysis of organic compounds in environmental samples by headspace solid phase microextractionJournal of High Resolution Chromatography, 1993
- On-line monitoring of flowing samples using solid phase microextraction-gas chromatographyAnalytica Chimica Acta, 1993
- Herbicide trace analysis by high-resolution fast atom bombardment mass spectrometry: quantification of low parts per trillion levels of atrazine in waterAnalytical Chemistry, 1993
- Determination of volatile chlorinated hydrocarbons in air and water with solid-phase microextractionThe Analyst, 1993
- Solventless injection technique for microcolumn separationsJournal of Microcolumn Separations, 1993
- Determination of atrazine in water at low- and sub-parts-per-trillion levels by using solid-phase extraction and gas chromatography/high-resolution mass spectrometryAnalytical Chemistry, 1993
- Environmental analysis of organic compounds in water using solid phase micro extractionJournal of High Resolution Chromatography, 1992