A New Pacemaker for Paroxysmal Atrial Fibrillation Treated with Radiofrequency Ablation of the AV Junction
- 1 November 1994
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 17 (11) , 1889-1894
- https://doi.org/10.1111/j.1540-8159.1994.tb03769.x
Abstract
Atrial fibrillation is a relative contraindication to atrial synchronous pacing because of the risk of the tracking of rapid atrial rhythms by the pacemaker. In this study, we describe the clinical results of an AV synchronous rate responsive pacemaker with an original algorithm, which is able to sense pathological increments in atrial rate and automatically to switch into a non‐AV synchronous mode of pacing. This pacemaker was implanted in 12 patients who had undergone radiofrequency ablation of the A V junction in order to cure severely symptomatic, drug refractory, paroxysmal atrial fibrillation. In an acute, intrapatient comparison between the standard AV synchronous mode and the automatic switching mode, ventricular tracking of atrial fibrillation occurred in 35% and 4% of total beats at rest and in 24% and 2% of total beats during exercise, respectively (P < 0.001). During 5 ± 4 months of follow‐up, no further tachyarrhythmia related symptoms occurred. In conclusion, the standard DDDR mode is unable to eliminate ventricular tracking of atrial fibrillation, thus undermining the efficacy of AV junction ablation therapy. The automatic switching mode eliminates this adverse effect of dual chamber pacing.Keywords
This publication has 7 references indexed in Scilit:
- Improvement in left ventricular function by ablation of atrioventricular nodal conduction in selected patients with lone atrial fibrillationThe American Journal of Cardiology, 1993
- Dual Chamber, Rate Adaptive Pacing in Patients with Paroxysmal Supraventricular Tachyarrhythmias: Protective Measures for Rate ControlPacing and Clinical Electrophysiology, 1993
- Use of a Dual Chamber Pacemaker with a Novel Fallback Algorithm as an Effective Treatment for Sick Sinus Syndrome Associated with Transient Supraventricular TachyarrhythmiaPacing and Clinical Electrophysiology, 1993
- Maintenance of Atrioventricular Sequence After His‐Bundle Ablation for Paroxysmal Supraventricular Rhythm Disorders: A Unique Use of the Fallback Mode in Dual Chamber PacemakersPacing and Clinical Electrophysiology, 1991
- Long-term follow-up of patients after transcatheter direct current ablation of the atrioventricular junctionJournal of the American College of Cardiology, 1990
- Sensor‐Driven Rate Smoothing in a DDDR PacemakerPacing and Clinical Electrophysiology, 1989
- Effect of catheter ablation of the atrioventricular junction on quality of life and exercise tolerance in paroxysmal atrial fibrillationThe American Journal of Cardiology, 1988