Abstract
We wished to establish a reproducible model for fracture fixation to be used in fracture healing research and therefore developed an external fixation construct and surgical procedure adapted to Sprague-Dawley rats. We evaluated the mechanical properties of the construct in brass rods and rat bone, in an Instron test machine with axial and transverse loading, and the in vivo performance. We found that the mechanical properties of the construct in brass rods were predictable and could be repeated in rat femora. In all tests, the axial load was about 10 times the transverse for the same degree of deformation. The stiffness among fixators was uniform. 1 mm pins caused about 50% less stiffness than 1.2 mm pins in axial loading of rat bone (p<0.001) and brass rods (p<0.001) as well as in transverse loading of brass rods (p<0.001). Loosening of 1 or 2 screws that lock the pins to the fixator reduced stiffness by about 50% in axial loading of rat bone (p=0.009) and brass rods (p=0.05). A change in the distance between the bone surface and the fixator was linearly related to the stiffness in axial loading of rat bone (p<0.001) and brass rods (p<0.001) and in transverse loading of brass rods (p<0.001). If the bone ends touched each other, the axial stiffness of the construct increased almost 10 times (265 N/mm), as compared to a fracture gap size of 2 mm (31 N/mm). In vivo experiments had a complication rate of less than 10% when we used 1.2 mm pins, 6 mm offset and rats weighing 350-450 g. Our method and device for experimental external fixation of rat femora are reliable and the findings are reproducible. These can be used in bone repair and fracture healing research.Keywords
This publication has 9 references indexed in Scilit:
- Bone and Cartilage Formation in an Experimental Model of Distraction OsteogenesisJournal of Orthopaedic Trauma, 1998
- Healing of a Segmental Defect in the Rat Femur with Use of an Extract from a Cultured Human Osteosarcoma Cell-Line (Saos-2). A Preliminary Report*Journal of Bone and Joint Surgery, 1996
- Induction of bone by a demineralized bone matrix gel: A study in a rat femoral defect modelJournal of Orthopaedic Research, 1995
- Differential fore- and hindpaw force transmission in the walking ratPhysiology & Behavior, 1995
- The role of fixator frame stiffness in the control of fracture healing. An experimental studyJournal of Biomechanics, 1993
- Enhancement of bone growth into metal screws implanted in the medullary canal of the femur in ratsJournal of Orthopaedic Research, 1993
- The healing of segmental bone defects induced by demineralized bone matrix. A radiographic and biomechanical study.Journal of Bone and Joint Surgery, 1984
- Production of a standard closed fracture in laboratory animal boneJournal of Orthopaedic Research, 1984