Performance of Five Different Assays for the Quantification of Viral Load in Persons Infected With Various Subtypes of HIV-1
- 1 February 2000
- journal article
- Published by Wolters Kluwer Health in JAIDS Journal of Acquired Immune Deficiency Syndromes
- Vol. 23 (2) , 138-144
- https://doi.org/10.1097/00126334-200002010-00005
Abstract
Five methods for the assessment of plasma viral load (VL) were evaluated in 103 seropositive patients infected with various subtypes of HIV-1. The methods included three RNA-based assays (Amplicor Monitor 1.5, Quantiplex version 2.0, NucliSens), one ultrasensitive reverse transcriptase (PERT) assay and one “boosted” p24 antigen (Ag) enzyme immunoassay (EIA). Subtyping was based on sequencing in env. The sensitivities were, in decreasing order, Amplicor > PERT > p24 Ag > NucliSens > Quantiplex. The low sensitivity of NucliSens was related to the missing of several non-B (A, E, F, G) or recombinant strains, whereas that of Quantiplex did not depend on subtype. In the 1 group O sample and 4 group M samples, only PERT assay or p24Ag EIA produced a positive result. In the quantitative range, correlation was best between Amplicor and Quantiplex (r = 0.8848), fair between Amplicor and NucliSens (r = 0.7064) or PERT assay (r = 0.7266), lowest between Amplicor and p24Ag EIA (r = 0.3989). Amplicor underestimated VL in 1 subtype E sample. Thus, Amplicor performed best in terms of sensitivity (compared with all other assays) and accuracy (compared with NucliSens, PERT assay, and p24Ag) for non-B subtypes in group M samples. PERT assay appears useful for VL assessment in infections by group O or other highly divergent viruses.Keywords
This publication has 42 references indexed in Scilit:
- Prospective Evaluation of Amplification‐Boosted ELISA for Heat‐Denatured p24 Antigen for Diagnosis and Monitoring of Pediatric Human Immunodeficiency Virus Type 1 InfectionThe Journal of Infectious Diseases, 1999
- Assay of Plasma Samples Representing Different HIV-1 Genetic Subtypes: An Evaluation of New Versions of the Amplicor HIV-1 Monitor AssayAIDS Research and Human Retroviruses, 1999
- Inaccurate HIV-1 viral load quantification by three major commercially available methodsAIDS, 1999
- Impact of HIV Type 1 Subtype Variation on Viral RNA QuantitationAIDS Research and Human Retroviruses, 1999
- Survival with AIDS in IrelandAIDS, 1997
- Reactivity and amplification efficiency of the NASBA HIV-1 RNA amplification system with regard to different HIV-1 subtypesJournal of Virological Methods, 1997
- Detection of Low HIV-1 RNA Levels in PlasmaJAIDS Journal of Acquired Immune Deficiency Syndromes, 1997
- Comparative evaluation of three assays for the quantitation of human immunodeficiency virus type 1 RNA in plasmaJournal of Medical Virology, 1996
- Sensitive detection and quantification of particle-associated reverse transcriptase in plasma of HIV-1-infected individuals by the product-enhanced reverse transcriptase (PERT) assayJournal of Medical Virology, 1996
- Ultrasensitive retrovirus detection by a reversetranscriptase assay based on product enhancement.Proceedings of the National Academy of Sciences, 1994