On the Nature and Elimination of Stimulus Artifact in Nerve Signals Evoked and Recorded Using Surface Electrodes
- 1 February 1982
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. BME-29 (2) , 129-137
- https://doi.org/10.1109/tbme.1982.325019
Abstract
The electrical stimulus pulse and the surface electrodes commonly used to study compound action potentials of peripheral nerves give rise to an artifact consisting of an initial spike and a longer lasting tail which often interferes with the recorded signal. The artifact has four sources: 1) the voltage gradient between the recording electordes caused by stimulus current flowing through the limb, 2) the common-mode voltage of the limb caused by current escaping through the ground electrode, 3) the capacitive coupling between the stimulating and recording leads, and 4) the high-pass filtering characteristics of the recording amplifier. This paper models these sources and presents several methodological rules for minimizing their effects. Also presented are three computer-based methods for subtracting the residual artifact from contaminated records using estimates of the artifact obtained from: 1) subthreshold stimulation, 2) a second recording site remote from the nerve, or 3) stimulation during the refractory period of the nerve.Keywords
This publication has 13 references indexed in Scilit:
- A fast-recovery electrode amplifier for electrophysiologyElectroencephalography and Clinical Neurophysiology, 1978
- A sample and hold amplifier system for stimulus artifact suppressionElectroencephalography and Clinical Neurophysiology, 1978
- Characteristics of the Metal-Tissue Interface of Stimulation ElectrodesIEEE Transactions on Biomedical Engineering, 1976
- A simplified circuit for stimulus artifact suppressionElectroencephalography and Clinical Neurophysiology, 1975
- Interface design for bioelectrode systemsIEEE Spectrum, 1972
- An electronic stimulus artifact suppressorElectroencephalography and Clinical Neurophysiology, 1971
- Low noise alternating current amplifier and compensator to reduce stimulus artefactMedical & Biological Engineering & Computing, 1970
- Nonlinearity of Cardiac Pacemaker ElectrodesIEEE Transactions on Biomedical Engineering, 1969
- The electrical properties of metal microelectrodesProceedings of the IEEE, 1968
- The current-voltage relationship in human skinMedical & Biological Engineering & Computing, 1963