A new method for quantification of image distortion due to pile-up in scintillation cameras
- 1 December 1991
- journal article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 18 (12) , 959-963
- https://doi.org/10.1007/bf00180416
Abstract
Characterization of the count-rate performance of scintillation cameras should include not only the specification of count losses. At high count rates, there is also an image distortion due to the mispositioning of pile-up events. In this paper a simple and clinically relevant procedure to quantify this distortion is presented. The images of a square uniform technetium-99m phantom at high and low count rates are used. The fraction of the total counts being correctly positioned is determined as the peripheral count density divided by the total average count density. This ratio, corrected for the camera non-uniformity at low count rates, is called the ‘positioning ability’. According to the National Electrical Manufacturers' Association (NEMA), the ‘system count rate performance with scatter’ should be reported as the measured count rate giving 20% count losses. In this paper it is suggested that this measure be complemented by a measure of the fraction correct positioned events at this count rate. This fraction, the ‘high count rate positioning ability', can be easily and accurately measured using our method. The method has been tested on two different scintillation cameras. For one of them the high count rate positioning ability was determined as 91% at a measured count rate of 30000 s−1 with 20% count losses. For the other camera, the corresponding figures were 88% at 59000 s−1 and close to 100% at 38000 s−1, before and after the installation of a new pile-up rejection circuit, respectively.Keywords
This publication has 7 references indexed in Scilit:
- EVALUATION OF A CLINICAL SCINTILLATION CAMERA WITH PULSE TAIL EXTRAPOLATION ELECTRONICS1989
- A COMPARISON OF COUNT RATE PARAMETERS IN GAMMA CAMERAS1981
- THEORETICAL-STUDIES OF IMAGE ARTIFACTS AND COUNTING LOSSES FOR DIFFERENT PHOTON FLUENCE RATES AND PULSE-HEIGHT DISTRIBUTIONS IN SINGLE-CRYSTAL NAL(TL) SCINTILLATION CAMERAS1980
- COMPARING PERFORMANCE OF 2 GAMMA-CAMERAS UNDER HIGH COUNTING RATES - PRINCIPLES AND PRACTICE1978
- IMAGE ARTIFACTS AT HIGH PHOTON FLUENCE RATES IN SINGLE-CRYSTAL NAL(TL) SCINTILLATION CAMERAS1978
- DEADTIME MEASUREMENTS IN SCINTILLATION CAMERAS UNDER SCATTER CONDITIONS SIMULATING QUANTITATIVE NUCLEAR CARDIOGRAPHY1978
- CLINICAL SIGNIFICANCE OF SCINTILLATION CAMERA ELECTRONICS CAPABLE OF HIGH PROCESSING RATES1977