Multifrequency ultrasound transducers for conformal interstitial thermal therapy
- 22 July 2003
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 50 (7) , 881-889
- https://doi.org/10.1109/tuffc.2003.1214507
Abstract
Control over the pattern of thermal damage generated by interstitial ultrasound heating applicators can be enhanced by changing the ultrasound frequency during heating. The ability to change transmission frequency from a single transducer through the use of high impedance front layers was investigated in this study. The transmission spectrum of multifrequency transducers was calculated using the KLM equivalent circuit model and verified with experimental measurements on prototype transducers. The addition of a quarter-wavelength thick PZT (unpoled) front layer enabled the transmission of ultrasound at two discrete frequencies, 4.7 and 9.7 MHz, from a transducer with an original resonant frequency of 8.4 MHz. Three frequency transmission at 3.3, 8.4, and 10.8 MHz was possible for a transducer with a half-wavelength thick front layer. Calculations of the predicted thermal lesion size at each transmission frequency indicated that the depth of thermal lesion could be varied by a factor of 1.6 for the quarter-wavelength front layer. Heating experiments performed in excised liver tissue with a dual-frequency applicator confirmed this ability to control the shape of thermal lesions during heating to generate a desired geometry. Practical interstitial Designs that enable the generation of shaped thermal lesions are feasible.Keywords
This publication has 23 references indexed in Scilit:
- Interstitial ultrasound heating applicator for MR-guided thermal therapy.Physics in Medicine & Biology, 2001
- Calculation of ultrasonic transducer signal-to-noise ratios using the KLM modelIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1997
- A new approach for the design of ultrasono-therapy transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1997
- Sound field calculation for rectangular sourcesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1989
- Design of Ultrasonic Transducers with Multiple Acoustic Matching Layers for Medical ApplicationIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1987
- Optimization of ultrasonic transducersUltrasonics, 1985
- Heat generation by ultrasound in a relaxing mediumThe Journal of the Acoustical Society of America, 1981
- The design of efficient broad-band piezoelectric transducersIEEE Transactions on Sonics and Ultrasonics, 1978
- New equivalent circuits for elementary piezoelectric transducersElectronics Letters, 1970
- The Effects of Backing and Matching on the Performance of Piezoelectric Ceramic TransducersIEEE Transactions on Sonics and Ultrasonics, 1966