There Is No Transmantle Pressure Gradient in Communicating or Noncommunicating Hydrocephalus
- 1 April 2002
- journal article
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 50 (4) , 763-773
- https://doi.org/10.1097/00006123-200204000-00016
Abstract
OBJECTIVE: To examine whether a transmantle pressure gradient exists in adult patients with communicating and noncommunicating hydrocephalus.METHODS: Ten patients participated in the study. The mean patient age was 57 ± 18 years (range, 20–80 yr); seven patients had communicating hydrocephalus, and three had noncommunicating hydrocephalus. Microsensors were used to measure the intracranial pressure (ICP), for 17 to 24 hours during sleeping and waking periods, in the right lateral ventricle (ICPIV) and in the subarachnoid space (ICPSAS) over the right cerebral convexity simultaneously. Patient activities and body positions were documented. The hydrostatic pressure difference between the two sensors was calculated from cranial x-rays for four basic body positions and compared with the actual body positions of the patients and the measured difference between the two sensors. For three 10-minute periods, the exact transmantle pressure gradient was calculated for each patient as ICPIV − ICPSAS, adjusted for the hydrostatic pressure difference.RESULTS: The measured pressure difference between the two sensors was always within the limits of the maximal possible hydrostatic pressure difference, and it correlated well with the expected difference for the various body positions: mean correlation coefficient, 0.79 ± 0.10 (range, 0.65–0.92). The exact mean transmantle pressure was −0.01 ± 0.24 mm Hg (range, −0.4 to 0.4 mm Hg). ICP waves caused by cardiac pulse, respiration, and B waves were identical in both spaces.CONCLUSION: This study demonstrates no factual support for existence of a transmantle pressure gradient in nonacute communicating or noncommunicating hydrocephalus.Keywords
This publication has 19 references indexed in Scilit:
- CRANIAL AND SPINAL COMPONENTS OF THE CEREBROSPINAL FLUID PRESSURE-VOLUME CURVEActa Neurologica Scandinavica, 2009
- Laboratory Testing of Three Intracranical Pressure Microtransducers: Technical ReportNeurosurgery, 1996
- The Evaluation of the Wave-form Analysis Capability of a New Strain-Gauge Intracranial Pressure MicroSensorNeurosurgery, 1995
- Monitoring of Brain Tissue Pressure with a Fiberoptic DeviceNeurosurgery, 1992
- Predictive value of quantitative cisternography in normal pressure hydrocephalusActa Neurologica Scandinavica, 1990
- Progressive ventricular enlargement in cats in the absence of transmantle pressure gradientsJournal of Neurosurgery, 1987
- Predictive value of the cerebrospinal fluid tap-testActa Neurologica Scandinavica, 1986
- Experimental normal-pressure hydrocephalus is accompanied by increased transmantle pressureJournal of Neurosurgery, 1984
- DETECTING INTRACRANIAL PRESSURE WAVES WITH ULTRASOUNDThe Lancet, 1972
- Cerebrospinal fluid production and histological observations in animals with experimental obstructive hydrocephalusExperimental Neurology, 1969