Myocardial contrast two-dimensional echocardiography: comparison of contrast disappearance rates in normal and underperfused myocardium.
- 1 February 1984
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 69 (2) , 418-429
- https://doi.org/10.1161/01.cir.69.2.418
Abstract
A computer algorithm was developed and applied to measure brightness decay rates of myocardial contrast opacification observed with two-dimensional echocardiography (2DE). An agitated mixture of diatrizoate meglumine and saline (Renografin-saline) was injected into the left main coronary artery of 17 closed-chest dogs during the control state as well as after placement of an intracoronary plug to induce 85% stenosis in the left anterior descending coronary artery (LAD) in five dogs. In 12 dogs, injections were also performed distally to complete intracoronary balloon occlusion of the LAD. For each injection, up to 35 electrocardiographic-gated, end-diastolic 2DE frames were digitized into an image-processing computer that determined mean pixel brightness of each of 12 myocardial segments per 2DE short-axis cross-section. Time-activity curves for each segment were generated, and contrast decay half-life (t 1/2) was calculated. Mean t 1/2 for control-state injections was found to be 24.1 +/- 7.7 sec, as opposed to 293.8 +/- 164.5 sec after complete coronary occlusion (p less than .001). In the five dogs in which 85% LAD stenosis was induced, prolongation of contrast t 1/2 from 18.3 +/- 8.9 sec during control to 44.3 +/- 21.0 sec (p less than .001) after plug insertion occurred in myocardial segments subserved by the stenosed vessel. No significant change occurred in segments that were not supplied by the stenosed vessel (21.9 +/- 9.1 sec during control vs 24.9 +/- 11.6 after plug insertion into the LAD). A reproducibility study of injection-to-injection t 1/2 in the control state indicated a correlation coefficient of r = .84 and a standard error of the estimate (SEE) equal to 5.86 sec, while interobserver t 1/2 reproducibility was r = .91 and SEE = 5.21 sec. The t 1/2 measurement derived by computer analysis of myocardial contrast 2DE may serve as an index for characterization of regional myocardial blood flow and may be applicable to evaluate interventions that alter perfusion.This publication has 22 references indexed in Scilit:
- Two-dimensional contrast echocardiography. I. In vitro development and quantitative analysis of echo contrast agentsJournal of the American College of Cardiology, 1984
- Direct measurement of microvessel hematocrit, red cell flux, velocity, and transit timeAmerican Journal of Physiology-Heart and Circulatory Physiology, 1982
- Microbubble formation: In vitro and in vivo observationJournal of Clinical Ultrasound, 1982
- Production of a critical coronary arterial stenosis in closed chest laboratory animals: Description of a new nonsurgical method based on standard cardiac catheterization techniquesThe American Journal of Cardiology, 1981
- Physiology and theory of tracer washout techniques for the estimation of myocardial blood flow: Flow estimation from tracer washoutProgress in Cardiovascular Diseases, 1977
- Measurement of regional myocardial blood flow in man: Description and critique of the method using xenon-133 and a scintillation cameraThe American Journal of Cardiology, 1975
- Effects of coronary stenoses on coronary flow reserve and resistancePublished by Elsevier ,1974
- Physiologic basis for assessing critical coronary stenosisThe American Journal of Cardiology, 1974
- Measurement of Regional Myocardial Perfusion in Man with 133Xenon and a Scintillation CameraJournal of Clinical Investigation, 1972
- Myocardial transit time: A new technic for evaluating coronary circulation I. Effect of systemic blood pressureThe American Journal of Cardiology, 1962