Selection of Was the X-Ray Wavelength Standard
- 25 January 1965
- journal article
- research article
- Published by American Physical Society (APS) in Physical Review B
- Vol. 137 (2B) , B455-B461
- https://doi.org/10.1103/physrev.137.b455
Abstract
Precision measurements have shown that the x-unit scale of x-ray wavelengths based on Mo xu is about 20 ppm smaller than that in general use for Cu and longer wavelengths, and for substantially all crystal parameters. Furthermore, the conversion from the Cu kxu to Å has been increased from 1.00202 to 1.002056±5 ppm. New techniques permit wavelength measurements to be made with relative probable errors of ±1 ppm. New wavelength and crystal-parameter tables are now necessary, and this plus the newly developed precision technique provides the opportunity for introducing an x-ray wavelength standard. In an investigation to select the best wavelength to be designated as the standard, the following studies have been carried out: relative measurements of five wavelengths with five crystals, employing a least-squares adjustment; -ray study of single-crystal diffraction patterns and the use of a -ray wavelength as a standard; crystal imperfections and their effect on wavelength measurements; effect of chemical impurities on grating constants; and redetermination of the absolute wavelength scale. The requirements of a standard are analyzed and the advantages of the W line listed. Its wavelength is 0.209010 0 ű5 ppm on the absolute scale, and without error as the designated standard. With this standard, new wavelength tables (separate publication) have been prepared, which include a large number of new measurements of secondary wavelength standards used as reference lines in many original measurements. Probable errors on both the relative and the absolute scale have been included.
Keywords
This publication has 22 references indexed in Scilit:
- X-Ray Wavelength Conversion FactorPhysical Review B, 1965
- Precision Redetermination of Standard Reference Wavelengths for X-Ray SpectroscopyPhysical Review B, 1964
- MEASUREMENT OF γ-RAY DIFFRACTION ANGLES TO ± 0.02 SECOND OF ARC WITH A DOUBLE FLAT CRYSTAL SPECTROMETERCanadian Journal of Physics, 1962
- Precision Measurement of theLX-Ray Spectra of Uranium and PlutoniumPhysical Review B, 1958
- The Variation of theResonating Strength with Atomic NumberPhysical Review B, 1934
- The Wave-Lengths of the Silver, Molybdenum, Copper, Iron and ChromiumLinesPhysical Review B, 1933
- Zur Dispersionstheorie der RöntgenstrahlenThe European Physical Journal A, 1933
- A Correction to Wave-length Measurements with the Double-Crystal SpectrometerPhysical Review B, 1932
- Über die Dispersion und Absorption von RöntgenstrahlenThe European Physical Journal A, 1928
- Über die Dispersion und Streuung von RöntgenstrahlenAnnalen der Physik, 1927