Deleterious effects of purulent sputum sol on human ciliary function in vitro: at least two factors identified.
Open Access
- 1 April 1987
- Vol. 42 (4) , 256-261
- https://doi.org/10.1136/thx.42.4.256
Abstract
Patients with chronic bronchial sepsis have impaired mucociliary clearance. A study was carried out on the effect of sputum sol (obtained by rapid centrifugation of purulent sputum) from 20 patients with chronic bronchial sepsis on the beating of human nasal cilia in vitro by a photometric technique. Thirteen sols caused significant (p less than 0.001) ciliary slowing. Two patterns of slowing were observed: firstly, a gradual onset associated with epithelial disruption (inhibited by alpha 1 antiprotease) and, secondly, an immediate onset associated with ciliary dyskinesia and ciliostasis (inhibited by chloroform extraction). The ciliary slowing activity of sputum sols was associated with the isolation of Pseudomonas aeruginosa (p less than 0.01). It is concluded that purulent sputum contains at least two factors that impair ciliary beating--one a serine protease, which is probably a product released by the host's phagocytic defences, and the other, which is chloroform extractable and probably a bacterial product.Keywords
This publication has 22 references indexed in Scilit:
- Pyocyanin and 1-hydroxyphenazine produced by Pseudomonas aeruginosa inhibit the beating of human respiratory cilia in vitro.Journal of Clinical Investigation, 1987
- Beat frequency of cilia from sites of purulent infection.Thorax, 1986
- Abnormal nasal mucociliary clearance in patients with rhinitis and its relationship to concomitant chest diseaseRespiratory Medicine, 1985
- Effect of bacterial products on human ciliary function in vitro.Thorax, 1985
- Reduction of ciliary beat frequency in vitro by sputum from patients with bronchiectasis: a serine proteinase effect.Thorax, 1984
- Elastolytic activity of sputum and its relation to purulence and to lung function in patients with bronchiectasis.Thorax, 1984
- An evaluation of four methods for the measurement of elastase activityClinica Chimica Acta; International Journal of Clinical Chemistry, 1981
- NON-INVASIVE SAMPLING OF NASAL CILIA FOR MEASUREMENT OF BEAT FREQUENCY AND STUDY OF ULTRASTRUCTUREThe Lancet, 1980
- The Immotile-Cilia SyndromeNew England Journal of Medicine, 1977
- HEALTH SERVICES, PAST, PRESENT AND FUTUREThe Lancet, 1958