End-tidal Carbon Dioxide Monitoring during Procedural Sedation
- 1 April 2002
- journal article
- research article
- Published by Wiley in Academic Emergency Medicine
- Vol. 9 (4) , 275-280
- https://doi.org/10.1111/j.1553-2712.2002.tb01318.x
Abstract
To prospectively determine whether end-tidal carbon dioxide (ETCO2) monitors can detect respiratory depression (RD) and the level of sedation in emergency department (ED) patients undergoing procedural sedation (PS). This was a prospective observational study conducted in an urban county hospital of adult patients undergoing PS. Patients were monitored for vital signs, depth of sedation per the physician by the Observer's Assessment of Alertness/Sedation scale (OAA/S), pulse oximetry, and nasal-sample ETCO2 during PS. Respiratory depression was defined as an oxygen saturation 50 mm Hg, or an absent ETCO2 waveform at any time during the procedure. The physician also determined whether protective airway reflexes were lost during the procedure and assisted ventilation was required, or whether there were any other complications. Rates of RD were compared with the physician assessment of airway loss and between agents using chi-square statistics. Spearman's rho analysis was used to determine whether there was a correlation between ETCO2 and the OAA/S score. Seventy-four patients were enrolled in the study. Forty (54.1%) received methohexital, 21 (28.4%) received propofol, ten (13.5%) received fentanyl and midazolam, and three (4.1%) received etomidate. Respiratory depression was seen in 33 (44.6%) patients, including 47.5% of patients receiving methohexital, 19% receiving propofol (p = 0.008), 80% receiving fentanyl and midazolam, and 66.6% receiving etomidate. No correlation between OAA/S and ETCO2 was detected. Eleven (14.9%) patients required assisted ventilation at some point during the procedure, all of whom met the criteria for RD. Pulse oximetry detected 11 of the 33 patients with RD. Post-hoc analysis revealed that all patients with RD had an ETCO2 >50 mm Hg, an absent waveform, or an absolute change from baseline in ETCO2 >10 mm Hg. There was no correlation between ETCO2 and the OAA/S score. Using the criteria of an ETCO2 >50 mm Hg, an absolute change >10 mm Hg, or an absent waveform may detect subclinical RD not detected by pulse oximetry alone. The ETCO2 may add to the safety of PS by quickly detecting hypoventilation during PS in the ED.Keywords
This publication has 18 references indexed in Scilit:
- Adverse events of procedural sedation and analgesia in a pediatric emergency departmentAnnals of Emergency Medicine, 1999
- Propofol for Emergency Department Procedural Sedation—Not Yet Ready for Prime TimeAcademic Emergency Medicine, 1999
- End-tidal carbon dioxide monitoring during sedation with a combination of midazolam and ketamine for children undergoing painful, invasive proceduresPediatric Emergency Care, 1999
- Procedural sedation and analgesia in the emergency department. Canadian consensus guidelinesThe Journal of Emergency Medicine, 1999
- Utility of monitoring capnography, pulse oximetry, and vital signs in the detection of airway mishaps: A hyperoxemic animal modelThe American Journal of Emergency Medicine, 1998
- Propofol Bolus Facilitates Reduction of Luxed Temporomandibular JointsThe Journal of Emergency Medicine, 1998
- Clinical Policy for Procedural Sedation and Analgesia in the Emergency DepartmentAnnals of Emergency Medicine, 1998
- Practical uses of end-tidal carbon dioxide monitoring in the emergency departmentThe Journal of Emergency Medicine, 1994
- Conscious sedation in the emergency department: The value of capnography and pulse oximetryAnnals of Emergency Medicine, 1992
- Utility of capnography in predicting venous carbon dioxide partial pressure in sedated patients during outpatient oral surgeryJournal of Oral and Maxillofacial Surgery, 1992