Intraoperative Myocardial Ischemia
Open Access
- 1 August 1988
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 69 (2) , 232-241
- https://doi.org/10.1097/00000542-198808000-00013
Abstract
Based primarily on results obtained during exercise treadmill testing, electrocardiographic (ECG) leads II and V5 are the suggested optimal leads for detecting intraoperative myocardial ischemia. However, these recommendations have not been validated in this setting using all 12 ECG leads. Accordingly, the authors studied 105 patients with known or suspected coronary artery disease (CAD) undergoing noncardiac surgery with general anesthesia by continuously recording the 12-lead ECG intraoperatively in all patients. The average duration of monitoring was 8.2 .+-. 2.7 h (mean .+-. SD). Ischemic episodes (i.e., .gtoreq. 1-mm horizontal or downsloping ST depression, .gtoreq. 1.5-mm slowly upsloping ST depression or .gtoreq. 1.5-1mm ST elevation in a non-Q wave lead) occurred in 25 patients (24%). Out of 51 ischemic episodes, 45 involved ST depression alone, and the remaining six involved both ST depression and elevation. ST segment changes occurred in a single lead only in 14 episodes, while multiple leads were involved in 37 episodes. Lead sensitivity was estimated assuming that all ST segment changes were true positive responses. Sensitivity using a single lead was greatest in V5 (75%) and V4 (61%), and intermediate in II, V3, and V6 (33%, 24%, and 37%, respectively). The remaining seven leads demonstrated very low sensitivity (2-14%) or exhibited no ischemic changes (I and a VL). Combining lead V4 and V5 increased sensitivity to 90%, while the standard clinical combination, II and V5, was only 80% sensitive. Sensitivity increased to 96% by combining II, V4, and V5. The further addition of V2 and V3 (five leads) increased sensitivity to 100%. This study confirms previous recommendations for the routine use of a V5 lead (either uni- or bipolar) in all patients at risk for ischemia. V4 is more sensitive than lead II, and should be considered as a second choice. However, lead II, superior for detection of atrial dysrhythmias, is more easily. obtained with conventional monitors. The use of three would appear to be the optimal arrangement for most clinical needs, and is recommended if the clinician has the capability.This publication has 15 references indexed in Scilit:
- Intraoperative detection of myocardial ischemia in high-risk patients: electrocardiography versus two-dimensional transesophageal echocardiography.Circulation, 1985
- Does Perioperative Myocardial Ischemia Lead to Postoperative Myocardial Infarction?Anesthesiology, 1985
- Morphology of ambulatory ST segment changes in patients with varying severity of coronary artery disease. Investigation of the frequency of nocturnal ischaemia and coronary spasm.Heart, 1985
- Prognostic value of Q waves, R/S ratio, loss of R wave voltage, ST-T segment abnormalities, electrical axis, low voltage and notching: Correlation of electrocardiogram and left ventriculogramJournal of the American College of Cardiology, 1984
- Reinfarction Following Anesthesia in Patients with Myocardial InfarctionAnesthesiology, 1983
- MYOCARDIAL ISCHAEMIA DURING DAILY LIFE IN PATIENTS WITH STABLE ANGINA: ITS RELATION TO SYMPTOMS AND HEART RATE CHANGESThe Lancet, 1983
- Electrocardiographic localization of coronary artery narrowings: studies during myocardial ischemia and infarction in patients with one-vessel disease.Circulation, 1982
- Vasospastic ischemic mechanism of frequent asymptomatic transient ST-T changes during continuous electrocardiographic monitoring in selected unstable angina patientsAmerican Heart Journal, 1982
- Myocardial Ischemia during Non-cardiac Surgical Procedures in Patients with Coronary-artery DiseaseAnesthesiology, 1979
- A new system of multiple-lead exercise electrocardiographyAmerican Heart Journal, 1966