Use of Polyetherurethane to Improve the Biocompatibility of Vascular Stents
- 1 August 1995
- journal article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 2 (3) , 255-265
- https://doi.org/10.1177/152660289500200304
Abstract
Purpose: To investigate potential differential growth of neointima following overdilating arterial trauma with polyetherurethane-coated versus bare metalìc stents in swine. Methods: Twelve specially constructed tantalum stents, 6 coated with polyetherurethane block copolymer and 6 uncoated, were overdilated by 25% in 12 normal renal arteries of six swine. The stents were harvested 8 weeks after implantation and prepared for histologic examination. Neointimal thickness was quantified and analyzed for significant differences between coated and uncoated prostheses. Results: All specimens demonstrated fractures of the internal elastic lamina consistent with vascular injury. There was significantly less neointimal formation (0.0001 < p < 0.05) in coated specimens as compared to uncoated controls in each test animal. Conclusion: The vascular response to overdilating stent trauma appears to be moderated with the use of polyetherurethane block copolymer as compared to control.Keywords
This publication has 12 references indexed in Scilit:
- Stent-induced Intimal Hyperplasia: Are There Fundamental Differences between Flexible and Rigid Stent Designs?Journal of Vascular and Interventional Radiology, 1994
- Decreased Platelet Adherence of Polymer-coated Tantalum StentsJournal of Vascular and Interventional Radiology, 1994
- Tantalum Balloon-expandable Stent: In Vivo Swine StudiesJournal of Vascular and Interventional Radiology, 1993
- The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting.Circulation, 1992
- Coronary intimal proliferation after balloon injury and stenting in swing: An animal model of restenosisJournal of the American College of Cardiology, 1992
- Novel approach to the analysis of restenosis after the use of three new coronary devicesJournal of the American College of Cardiology, 1992
- Adjuvant antiplatelet strategies in coronary thrombolysis.Circulation, 1991
- Restenosis after balloon angioplasty. A practical proliferative model in porcine coronary arteries.Circulation, 1990
- Investigation of three‐surface properties of several metals and their relation to blood compatibilityJournal of Biomedical Materials Research, 1972
- Initial events in interactions of blood with a foreign surfaceJournal of Biomedical Materials Research, 1969