Increasing throughput and information content for in vitro drug metabolism experiments using ultra‐performance liquid chromatography coupled to a quadrupole time‐of‐flight mass spectrometer
- 18 February 2005
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 19 (6) , 843-848
- https://doi.org/10.1002/rcm.1859
Abstract
The field of drug metabolism has been revolutionized by liquid chromatography/mass spectrometry (LC/MS) applications with new technologies such as triple quadrupoles, ion traps and time-of-flight (ToF) instrumentation. Over the years, these developments have often relied on the improvements to the mass spectrometer hardware and software, which has allowed users to benefit from lower levels of detection and ease-of-use. One area in which the development pace has been slower is in high-performance liquid chromatography (HPLC). In the case of metabolite identification, where there are many challenges due to the complex nature of the biological matrices and the diversity of the metabolites produced, there is a need to obtain the most accurate data possible. Reactive or toxic metabolites need to be detected and identified as early as possible in the drug discovery process, in order to reduce the very costly attrition of compounds in late-phase development. High-resolution, exact mass measurement plays a very important role in metabolite identification because it allows the elimination of false positives and the determination of non-trivial metabolites in a much faster throughput environment than any other standard current methodology available to this field. By improving the chromatographic resolution, increased peak capacity can be achieved with a reduction in the number of co-eluting species leading to superior separations. The overall enhancement in the chromatographic resolution and peak capacity is transferred into a net reduction in ion suppression leading to an improvement in the MS sensitivity. To investigate this, a number of in vitro samples were analyzed using an ultra-performance liquid chromatography (UPLC) system, with columns packed with porous 1.7 μm particles, coupled to a hybrid quadrupole time-of-flight (ToF) mass spectrometer. This technique showed very clear examples for fundamental gains in sensitivity, chromatographic resolution and speed of analysis, which are all important factors for the demands of today's HTS in discovery. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 10 references indexed in Scilit:
- Direct analysis of pharmaceutical compounds in human plasma with chromatographic resolution using an alkyl‐bonded silica rod columnRapid Communications in Mass Spectrometry, 2001
- Use of monolithic silica columns to increase analytical throughput for metabolite identification by liquid chromatography/tandem mass spectrometryRapid Communications in Mass Spectrometry, 2000
- Parallel ultra-high flow rate liquid chromatography with mass spectrometric detection using a multiplex electrospray source for direct, sensitive determination of pharmaceuticals in plasma at extremely high throughputRapid Communications in Mass Spectrometry, 2000
- Bioanalytical applications of ?fast chromatography? to high-throughput liquid chromatography/tandem mass spectrometric quantitationRapid Communications in Mass Spectrometry, 2000
- The need for adequate chromatographic separation in the quantitative determination of drugs in biological samples by high performance liquid chromatography with tandem mass spectrometryRapid Communications in Mass Spectrometry, 1999
- LC/MS applications in drug developmentMass Spectrometry Reviews, 1999
- Use of generic fast gradient liquid chromatography–tandem mass spectroscopy in quantitative bioanalysisJournal of Chromatography B: Biomedical Sciences and Applications, 1998
- Application of a generic fast gradient liquid chromatography tandem mass spectrometry method for the analysis of cytochrome P450 probe substratesRapid Communications in Mass Spectrometry, 1998
- Use of short columns and high flow rates for rapid gradient reversed-phase chromatographyChromatographia, 1998
- The Use of Automated Solid Phase Extraction in the '96 well' Format for High Throughput Bioanalysis using Liquid Chromatography Coupled to Tandem Mass SpectrometryRapid Communications in Mass Spectrometry, 1996