In Situ Measurement of Reaction Volume and Calculation of pH of Weak Acid Buffer Solutions Under High Pressure
- 4 May 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 115 (20) , 6564-6571
- https://doi.org/10.1021/jp1110295
Abstract
Direct measurements of reaction volume, so far, have been limited to atmospheric pressure. This study describes a method for in situ reaction volume measurements under pressure using a variable volume piezometer. Reaction volumes for protonic ionization of weak acid buffering agents (MES, citric acid, sulfanilic acid, and phosphoric acid) were measured in situ under pressure up to 400 MPa at 25 °C. The methodology involved initial separation of buffering agents within the piezometer using gelatin capsules. Under pressure, the volume of the reactants was measured at 25 °C, and the contents were heated to 40 °C to dissolve the gelatin and allow the reaction to occur, and cooled to 25 °C, where the volume of products was measured. Reaction volumes were used to calculate pH of the buffer solutions as a function of pressure. The results show that the measured reaction volumes as well as the calculated pH values generally quite agree with their respective theoretically predicted values up to 100 MPa. The results of this study highlight the need for a comprehensive theory to describe the pressure behavior of ionization reactions in realistic systems especially at higher pressures.This publication has 29 references indexed in Scilit:
- In Situ Measurement of pH Under High PressureThe Journal of Physical Chemistry B, 2010
- Variable volume piezometer for measurement of volumetric properties of materials under high pressureHigh Pressure Research, 2009
- Buffer selection for HP treatment of biomaterials and its consequences for enzyme inactivation studiesHigh Pressure Research, 2007
- Electrochemical measurements at high pressure: solvation and the thermodynamics of electron-transfer reactionsThe Journal of Physical Chemistry, 1992
- pH Measurements in Aqueous CO2Solutions under High Pressure and TemperatureCorrosion, 1983
- The Effect of Pressure on the Dissociation of Weak Acids in Aqueous BuffersBulletin of the Chemical Society of Japan, 1976
- Some quantitative relationships for ionization reactions at high pressuresAustralian Journal of Chemistry, 1975
- The Effect of Pressure on the Dissociation of Carbonic Acid from Measurements with Buffered Glass Electrode CellsJournal of the Electrochemical Society, 1967
- Volume Changes in Protein Reactions. II. Comparison of Ionization Reactions in Proteins and Small MoleculesJournal of the American Chemical Society, 1962
- Ueber das Princip der Vermehrung der EntropieAnnalen der Physik, 1887