Nuclear Magnetic Resonance Measurements in Oil-Nitrogen Two-Phase Flow
Open Access
- 1 September 1995
- journal article
- Published by Walter de Gruyter GmbH in Zeitschrift für Naturforschung A
- Vol. 50 (9) , 845-851
- https://doi.org/10.1515/zna-1995-0909
Abstract
NMR measurements of the oil mass flow have been carried out in all-oil flow as well as in oil-nitrogen two-phase flow. For the calibration a simplified method was used which circumvents spin-lattice relaxation calculations due to the short polarization time of the protons at rather high flow velocities. With this method an overall accuracy of the oil-flow in oil-nitrogen two-phase flow of about ±5% was achieved. Some proposals for an improvement of the NMR apparatus are made, which would render the evaluations simpler and more accurate.Keywords