Percutaneous entry of the brachial artery for left heart catheterization using a sheath
- 1 January 1981
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 7 (1) , 111-114
- https://doi.org/10.1002/ccd.1810070116
Abstract
Percutaneous entry of the brachial artery using a sheath system has been attempted in 223 patients undergoing left heart Catheterization; successfully, In 212. After arterial puncture, a dilator and sheath are passed over a short guWewire. A number 7–80 cm Sones specially stiffened coronary catheter Is passed through the sheath, and left heart Catheterization Is performed in the usual manner. The study can usually be completed with this single catheter. Initial entry, as well as any needed catheter change, Is facilitated by the use of an inflatable sphygmomanometer cuff around the upper arm. Ease of manipulation and patient comfort have been satisfactory, and brachial artery spasm has not been encountered. There have been no major complications and a low incidence (∼ 1.5%) of brachial arterial occlusion.Keywords
This publication has 4 references indexed in Scilit:
- Complications of coronary arteriography from the Collaborative Study of Coronary Artery Surgery (CASS).Circulation, 1979
- Left heart catheterization and angiography via the percutaneous femoral approach using an arterial sheathCatheterization and Cardiovascular Diagnosis, 1979
- Percutaneous left heart catheterization and coronary arteriography using a femoral artery sheathCatheterization and Cardiovascular Diagnosis, 1979
- Catheter Replacement of the Needle in Percutaneous Arteriography: A new techniqueActa Radiologica, 1953