Tissue Reaction to Metal on Metal Total Hip Prostheses
- 1 August 1996
- journal article
- association of-bone-and-joint-surgeons-workshop
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 329, S187-S205
- https://doi.org/10.1097/00003086-199608001-00017
Abstract
The periprosthetic tissue reaction to polyethylene wear debris in metal on polyethylene total hip replacements is strongly implicated as the cause of osteolysis. This has led to a renewed interest in metal on metal total hip replacements. However, little is known about the role of wear debris in failures of these prostheses. Capsular and interface tissues from 9 long and short term metal on metal total hip replacement retrievals were studied to assess the tissue reaction around these prostheses. As compared with metal on polyethylene cases, the extent of the granulomatous inflammatory reaction and the presence of foreign body type giant cells was much less intense in metal on metal cases, likely because of the lower numbers and overall smaller size of metal wear debris particles. This may lead to a better transport of the particles from the joint tissues and a lower incidence of periprosthetic osteolysis around metal on metal hip replacement.Keywords
This publication has 28 references indexed in Scilit:
- Response of three murine macrophage populations to particulate debris: Bone resorption in organ culturesJournal of Orthopaedic Research, 1994
- Light microscopic identification of submicron polyethylene wear debrisJournal of Applied Biomaterials, 1993
- Fibroblast response to metallic debris in vitro. Enzyme induction cell proliferation, and toxicity.Journal of Bone and Joint Surgery, 1993
- Titanium wear debris in failed cemented total hip arthroplasty: An analysis of 71 casesThe Journal of Arthroplasty, 1992
- Resorption of bone by inflammatory cells derived from the joint capsule of hip arthroplastiesThe Journal of Bone and Joint Surgery. British volume, 1992
- Tissue response in relation to type of wear particles around failed hip arthroplastiesThe Journal of Arthroplasty, 1990
- Bone lysis in well-fixed cemented femoral componentsThe Journal of Bone and Joint Surgery. British volume, 1990
- Metallic wear in failed titanium-alloy total hip replacements. A histological and quantitative analysis.Journal of Bone and Joint Surgery, 1988
- COBALT TOXICITY AFTER McKEE HIP ARTHROPLASTYThe Journal of Bone and Joint Surgery. British volume, 1975
- Total Hip Replacement FailuresJournal of Bone and Joint Surgery, 1973