Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures
- 1 May 1982
- journal article
- research article
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 43 (5) , 1104-1110
- https://doi.org/10.1128/aem.43.5.1104-1110.1982
Abstract
Samples obtained from plumbing systems of hospitals, nonhospital institutions and homes were cultured for Legionella spp. by plating the samples directly on a selective medium. Swab samples were taken from the inner surfaces of faucet assemblies (aerators, spouts, and valve seats), showerheads, and shower pipes. Water and sediment were collected from the bottom of hot-water tanks. Legionella pneumophila serogroups 1, 5, and 6 were recovered from plumbing fixtures of the hospitals and nonhospital institutions and one of five homes. The legionellae (7 to 13,850 colony-forming units per ml) were also present in water and sediment from hot-water tanks maintained at 30 to 54 degrees C, but not in those maintained at 71 and 77 degrees C. Legionella micdadei was isolated from one tank. Thus legionellae are present in hot-water tanks which are maintained at warm temperatures or whose design results in warm temperatures at the bottom of the tanks. We hypothesize that hot-water tanks are a breeding site and a major source of L. pneumophila for the contamination of plumbing systems. The existence of these bacteria in the plumbing systems and tanks was not necessarily associated with disease. The extent of the hazard of this contamination needs to be delineated.This publication has 21 references indexed in Scilit:
- Successful treatment of Legionella micdadei (Pittsburgh pneumonia agent) pneumonia with erythromycinThe American Journal of Medicine, 1981
- INVESTIGATION AND CONTROL OF AN OUTBREAK OF LEGIONNAIRES' DISEASE IN A DISTRICT GENERAL HOSPITALThe Lancet, 1981
- Isolation of Legionella pneumophila from water systems: methods and preliminary results.BMJ, 1981
- Isolation of Legionella pneumophila from Hospital Shower HeadsAnnals of Internal Medicine, 1981
- LEGIONNAIRES' DISEASE IN A TRANSPLANT UNIT: ISOLATION OF THE CAUSATIVE AGENT FROM SHOWER BATHSThe Lancet, 1980
- Pittsburgh Pneumonia Agent: Direct Isolation from Human Lung TissueThe Journal of Infectious Diseases, 1980
- An Outbreak of Legionnaires' Disease Associated with a Contaminated Air-Conditioning Cooling TowerNew England Journal of Medicine, 1980
- NEW BACTERIAL AGENT OF PNEUMONIA ISOLATED FROM RENAL-TRANSPLANT RECIPIENTSThe Lancet, 1979
- A Major Focus of Legionnaires' Disease in Bloomington, IndianaAnnals of Internal Medicine, 1979
- Detection of Legionnaires disease bacteria by direct immunofluorescent stainingJournal of Clinical Microbiology, 1978