A comparative study of porous coatings in a weight-bearing total hip-arthroplasty model.
- 1 December 1986
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 68 (9) , 1396-1409
- https://doi.org/10.2106/00004623-198668090-00013
Abstract
The purposes of this study were to compare ingrowth of bone into three types of porous coating and to determine the effect of the type of porous coating and the degree of coverage of the stem on the remodeling of bone on the femoral side in cementless hip arthroplasty. A left total hip arthroplasty was performed in forty dogs. Thirty of the dogs had a titanium-alloy femoral prosthesis that had had one of three types of commercially pure titanium porous material applied along the length of the anterior and posterior surfaces of the stem: ten with sintered fiber-metal, ten with sintered beads, and ten with plasma flame-spray coating. The remaining ten dogs had a femoral component that was circumferentially coated with commercially pure titanium that was plasma flame-sprayed along the length of the stem. In each group, five animals were killed at one month and five were killed at six months. Ingrowth of bone into all three types of porous coating was observed, indicating secure fixation of all components. By six months, there was more ingrowth of bone and new medullary bone adjacent to the proximal and distal aspects of the stems compared with the middle level of the stems in all groups. No significant difference in ingrowth of bone was observed in the beaded surface (25.2 per cent) and the fiber-metal surface (16.6 per cent) at one month, but at six months there was significantly less ingrowth into the beaded surface (23.3 per cent) than into the fiber-metal surface (37.3 per cent). In all groups, a proximal-to-distal gradient of loss of cortical bone was observed by six months. The group of dogs that had the stem with the circumferential coating experienced more severe loss of bone than did the three groups that had a stem with a partial coating. The magnitude of loss of bone was dependent on the extent rather than the type of porous coating.Keywords
This publication has 8 references indexed in Scilit:
- Tibial changes in experimental disuse osteoporosis in the monkeyCalcified Tissue International, 1983
- In vivo strain measurements from bone and prosthesis following total hip replacement. An experimental study in sheep.Journal of Bone and Joint Surgery, 1981
- Interface mechanics of porous titanium implantsJournal of Biomedical Materials Research, 1981
- Proximal strain distribution in the loaded femur. An in vitro comparison of the distributions in the intact femur and after insertion of different hip-replacement femoral components.Journal of Bone and Joint Surgery, 1978
- Factors governing the mechanical behavior of the implant-porous coating-trabecular bone interfaceJournal of Biomechanics, 1978
- The rate of bone ingrowth into porous metalJournal of Biomedical Materials Research, 1976
- Changes in resorption spaces in femoral cortical bone with ageThe Journal of Pathology and Bacteriology, 1965
- Microangiography in Bone HealingJournal of Bone and Joint Surgery, 1962