Amperometric Sensors for Simultaneous Superoxide and Hydrogen Peroxide Detection
- 1 February 1997
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 69 (3) , 454-462
- https://doi.org/10.1021/ac9606261
Abstract
A two-channel sensor capable of almost instantaneous simultaneous detection of superoxide radical and hydrogen peroxide in the concentration range 10-7−10-4 M is very important for understanding of a number of rapid kinetics processes. A glassy carbon working microelectrode covered by an electrodeposited polypyrrole/horseradish peroxidase (PPy/HRP) membrane was employed as a H2O2 sensor. Another glassy carbon microelectrode covered by a composite membrane of an inside layer of PPy/HRP and an outside layer of superoxide dismutase was employed as a working electrode for superoxide detection. These two working electrodes with Pt counter and tungsten oxide (WO3) reference electrodes were contained in one 6 mm diameter Teflon cylinder. Simultaneous measurements were performed at a potential of −60 mV (vs WO3 reference, pH 5.1). Additional sensor characterization was performed for pH 5.1−9.0. Superoxide sensor behavior as a function of membrane deposition conditions and coating time is reported. Sensors' mutual influence, selectivity, response times, linearity, stability, and sensitivity for hydrogen peroxide and superoxide are presented and discussed. A mathematical model of sensors' responses is proposed, with model calculation corresponding to experiment within 10%.Keywords
This publication has 19 references indexed in Scilit:
- Period-doubling bifurcations and chaos in a detailed model of the peroxidase-oxidase reactionThe Journal of Physical Chemistry, 1995
- Transient Response of Multilayer Electroenzymic BiosensorsAnalytical Chemistry, 1995
- Xanthine Oxidase Reactivity in Reversed Micellar Systems: A Contribution to the Prediction of Enzymic Activity in Organized MediaJournal of the American Chemical Society, 1995
- The peroxidase—NADH biochemical oscillator: experimental system, control variables, and oxygen mass transportAnalytica Chimica Acta, 1993
- Hydrogen peroxide and .beta.-nicotinamide adenine dinucleotide sensing amperometric electrodes based on electrical connection of horseradish peroxidase redox centers to electrodes through a three-dimensional electron relaying polymer networkAnalytical Chemistry, 1992
- Model analysis of enzyme monolayer- and bilayer-modified electrodes: the transient responseAnalytical Chemistry, 1992
- Enzyme monolayer- and bilayer-modified tin oxide electrodes for the determination of hydrogen peroxide and glucoseAnalytical Chemistry, 1989
- Model of a two-substrate enzyme electrode for glucoseAnalytical Chemistry, 1984
- Covalent linkage of glucose oxidase on modified glassy carbon electrodes. Kinetic phenomenaJournal of the American Chemical Society, 1980